Y6-30 Small Boiler Centrifugal Induced Draft Fan

Y6-30 Small Boiler Centrifugal Induced Draft Fan

Y6-30 Small Boiler Centrifugal Induced Draft Fan is designed for induced draft systems of small industrial boilers. It is suitable for 0.2t/h to 4t/h boiler applications, helping exhaust flue gas and maintain stable boiler draft. The fan can be supplied with C type or D type transmission, left-hand or right-hand rotation, and different outlet angles according to site installation requirements.
Send Inquiry
Description
Small Boiler Induced Draft Fan | 0.2t/h to 4t/h Boiler Matching

Y6-30 Small Boiler Centrifugal Induced Draft Fan

Y6-30 Small Boiler Centrifugal Induced Draft Fan is designed for small industrial boiler induced draft systems. It helps exhaust flue gas, maintain stable boiler draft and match compact boiler room installations for 0.2t/h to 4t/h boiler applications.

Small Boiler Room Matching
Matched Boiler
0.2t/h – 4t/h small boiler
Fan Function
Flue gas exhaust and draft stabilization
Model Range
No.3.5C – No.8.6C reference range
Installation
Left / right rotation and multiple outlet angles

Designed for Small Boiler Induced Draft

The Y6-30 series is used for small boiler induced draft applications rather than large power plant boiler systems. It is suitable for compact boiler rooms where the fan needs to remove flue gas, maintain negative pressure and work with limited installation space.

Compared with larger boiler fan series, Y6-30 focuses on small boiler matching, moderate airflow, compact transmission arrangement and flexible outlet direction. It is commonly selected for 0.2t/h, 0.5t/h, 1t/h, 2t/h and 4t/h boiler exhaust draft systems.

Boiler Draft Application Logic

Step 01
Flue Gas Collection

The induced draft fan helps pull flue gas from the boiler outlet and guide it into the exhaust duct system.

Step 02
Draft Stability

Suitable pressure helps maintain stable boiler draft and supports normal combustion conditions.

Step 03
Boiler Room Exhaust

The fan supports small boiler exhaust systems in workshops, heating rooms and compact industrial facilities.

Step 04
Site Matching

Rotation direction, outlet angle and transmission arrangement can be confirmed according to the installation layout.

Structure and Installation Options

Item
Configuration Description
Fan Series
Y6-30 small boiler centrifugal induced draft fan
Main Components
Impeller, casing, air regulating damper, transmission part and air inlet
Drive Type
C type and D type transmission options according to fan configuration
Rotation Direction
Right-hand or left-hand rotation when viewed from the motor side
Outlet Direction
0° standard direction, with 45°, 90°, 135°, 180° and 225° options when required
Selection Basis
Boiler capacity, airflow, pressure, flue gas condition, duct layout and installation angle

Reference Performance Parameters

The following data is for preliminary model selection. Final selection should be confirmed according to boiler capacity, airflow, total pressure, duct resistance, outlet angle, drive type and site installation conditions.

Item
Reference Data
Model Range
No.3.5C – No.8.6C
Matched Boiler
0.2t/h – 4t/h
Air Volume
655 – 17262 m³/h
Total Pressure
727 – 3226 Pa
Speed
1800 – 2350 r/min reference range
Motor Power
0.75 – 22 kW

Representative Model Parameters

Model
Speed
Air Volume
Total Pressure
Power
Boiler
3.5C
2350 r/min
655–1192 m³/h
853–727 Pa
0.75 kW
0.2 t/h
4.3C
approx. 2260 r/min
1169–2125 m³/h
1206–1020 Pa
1.5 kW
0.2 t/h
4.8C
2250 r/min
1060–2944 m³/h
1490–1265 Pa
2.2 kW
0.5 t/h
5.4C
2300 r/min
2202–3963 m³/h
2157–1833 Pa
3 kW
0.5 t/h
6.5C
2150 r/min
2926–4945 m³/h
2433–2020 Pa
4–5.5 kW
1 t/h
7.5C
1900 r/min
5216–8771 m³/h
2598–2196 Pa
7.5–11 kW
2 t/h
8.6C
1850 r/min
9494–17262 m³/h
3226–2736 Pa
18.5–22 kW
4 t/h

Typical Use Cases

Small industrial boiler room
0.2t/h to 4t/h boiler exhaust system
Factory heating boiler
Workshop small boiler draft system
Boiler flue gas exhaust
Compact boiler room renovation

Information Required for Fan Selection

To recommend a suitable Y6-30 induced draft fan model, please provide the following working conditions. These details help match fan performance with your boiler room exhaust system.

Boiler capacity
Required airflow volume
Static pressure or total pressure
Flue gas temperature
Duct layout and resistance
Outlet angle requirement
Rotation direction
Drive type and installation space

Need a Y6-30 Small Boiler Fan Selection?

Send us your boiler capacity, airflow, pressure, flue gas condition, outlet angle and installation requirements. Qiyue Fan can help recommend a suitable Y6-30 centrifugal induced draft fan for your small boiler system.

Manager Zhao
Industrial Ventilation Fan Supplier
SHANDONG QIYUE FAN CO., LTD.
Tel / WeChat / WhatsApp: +86 15653305981  |  Email: sales@qiyuefan.com

Hot Tags: y6-30 small boiler centrifugal induced draft fan, China y6-30 small boiler centrifugal induced draft fan manufacturers, suppliers, factory

Send Inquiry