GY5-51 Boiler Centrifugal Forced Draft and Induced Draft Fan

GY5-51 Boiler Centrifugal Forced Draft and Induced Draft Fan

GY5-51 Boiler Centrifugal Forced Draft and Induced Draft Fan is designed for forced draft and induced draft systems of steam boilers in thermal power plants. It is suitable for 2t/h to 670t/h boilers and can also meet the high-pressure requirements of fluidized bed boilers. The forced draft fan conveys air, while the induced draft fan conveys flue gas or gas containing impurity particles. The operating temperature should not exceed 250°C.
Send Inquiry
Description
Boiler Forced Draft and Induced Draft Fan Series

GY5-51 Boiler
Forced / Induced Draft Fan

 

GY5-51 is a boiler centrifugal fan series for steam-boiler forced-draft and induced-draft systems. It is suitable for 2–670 t/h boilers and can also support higher-pressure fluidized-bed boiler ventilation duties.

G5-51 is mainly used on the clean-air side for combustion-air supply. Y5-51 is mainly used on the flue-gas side for induced draft and negative-pressure support.

Final selection should include fan position, airflow, total pressure, gas temperature, dust concentration, outlet angle, rotation direction, voltage and site layout.

GY5-51 boiler forced draft and induced draft fan for steam boiler and fluidized bed boiler systems
Clean-Air Side
G5-51 Forced Draft
Flue-Gas Side
Y5-51 Induced Draft
Boiler Range
2–670 t/h
Model Range
No.8D–29.5D
D-type cantilever structure with elastic coupling drive; rotation and outlet angle matched to the site layout.
Forced Draft Medium
Clean Air
Combustion-air supply before the boiler or furnace.
Induced Draft Medium
Flue Gas
Exhaust and negative-pressure support after combustion.
Temperature Limit
≤250°C
Higher-temperature duty requires a separate review.
Recommended Dust
<200 mg/m³
Lower impurity concentration supports longer service life.
Product Positioning

One Series, Two Different Boiler Draft Positions

GY5-51 covers both boiler forced-draft and induced-draft directions, but G5-51 and Y5-51 should not be treated as the same working condition. The medium, temperature, dust loading and system resistance change across the boiler air path.

G5-51 mainly handles clean combustion air. Y5-51 handles flue gas or gas containing impurity particles. The fan position should therefore be confirmed before comparing model number, motor power or casing size.

The letter "G" generally represents forced draft, while "Y" represents induced draft. Final configuration still depends on the actual operating point and site conditions.
Boiler Draft Logic

How G5-51 and Y5-51 Work in the Same System

01 · Clean-Air Intake

Fresh or preheated air enters the combustion-air side.

02 · G5-51 Forced Draft

Pushes combustion air toward the boiler or furnace.

03 · Boiler and Collector

Combustion, heat exchange and dust-treatment resistance occur here.

04 · Y5-51 Induced Draft

Pulls flue gas through the exhaust route and supports negative pressure.

G5-51 vs Y5-51

Forced-Draft and Induced-Draft Comparison

Selection Point G5-51 Forced Draft Y5-51 Induced Draft What to Confirm
Fan Position Before the boiler or furnace After combustion and treatment equipment Complete boiler air-path layout
Medium Clean or preheated air Flue gas with possible impurity particles Dust, temperature and corrosion risk
Pressure Source Air-side duct and burner resistance Boiler, collector, duct and chimney resistance Total system pressure loss
Main Goal Supply combustion air Maintain exhaust flow and negative pressure Required operating point and control method
Main Features

GY5-51 Configuration and Application Characteristics

Forced and Induced Draft Use

The series covers both combustion-air supply and flue-gas extraction directions.

2–670 t/h Boiler Range

Suitable for steam-boiler systems, industrial boiler rooms and thermal-power applications.

Fluidized-Bed Boiler Support

Can meet higher-pressure requirements in fluidized-bed boiler ventilation systems.

D-Type Coupling Drive

Cantilever structure and elastic coupling transmission support stable operation.

Left or Right Rotation

Rotation and outlet angle can be matched to the site duct and foundation layout.

Multi-Condition Application

May also be reviewed for dust removal, mine ventilation and general industrial ventilation.

Reference Technical Parameters

GY5-51 Series Configuration Reference

The following data is for preliminary review. Final selection should be confirmed according to boiler capacity, airflow, pressure, medium condition, temperature and site layout.

Item Reference Data
Fan Series GY5-51 Series
Fan Type Boiler forced-draft fan and induced-draft fan
Boiler Capacity 2–670 t/h steam boiler
Model Range No.8D–No.29.5D
Drive Type D type, cantilever structure with elastic coupling direct transmission
Forced Draft Medium Air
Induced Draft Medium Flue gas or gas containing impurity particles
Impurity Concentration Below 200 mg/m³ recommended for longer service life
Working Temperature ≤250°C
Rotation Direction Left-hand or right-hand rotation
G5-51 Performance Direction

G5-51 Boiler Forced Draft Fan

The following representative data is for preliminary forced-draft model comparison.

Model Speed Air Volume Total Pressure Power Motor
8D 1450 r/min 9,900–14,300 m³/h 2,525–2,423 Pa 15 kW Y160L-4
10D 1450 r/min 30,300–37,900 m³/h 4,944–3,804 Pa 45 kW Y225M-4
12D 1450 r/min 55,400–68,200 m³/h 6,656–5,429 Pa 110 kW Y315S-4
16D 1450 r/min 79,100–185,000 m³/h 10,095–7,083 Pa 450–550 kW Y400-4
20D 960 r/min 140,000–182,000 m³/h 6,156–2,809 Pa 400 kW Y400-6
Y5-51 Performance Direction

Y5-51 Boiler Induced Draft Fan

The following representative data is for preliminary induced-draft model comparison.

Model Speed Air Volume Total Pressure Power Motor
8D 1450 r/min 9,900–15,500 m³/h 1,568–1,455 Pa 11 kW Y160M-4
10D 1450 r/min 26,500–45,100 m³/h 2,104–1,718 Pa 37 kW Y225S-4
12D 1450 r/min 33,400–46,200 m³/h 3,525–3,401 Pa 75 kW Y280S-4
13D 1450 r/min 70,700–80,200 m³/h 3,847–3,556 Pa 132 kW Y315M1-4
15D 1450 r/min 65,100–152,000 m³/h 6,509–3,865 Pa 220–315 kW Y355-4
Quotation Data

Information Required for Fan Selection

01 · Fan Position

Confirm forced draft or induced draft before comparing model data.

02 · Airflow and Pressure

Provide required airflow and static or total pressure basis.

03 · Medium Condition

Confirm gas temperature, dust loading, impurity concentration and corrosion risk.

04 · Installation Data

Provide outlet angle, rotation, voltage, motor standard and site layout.

Related Selection Paths

Continue from GY5-51 to Product Family, System and Related Models

Use the product-family and system pages to confirm the correct side of the boiler air path. Specific product links remain available for direct comparison.

Boiler Forced Draft Fans

Use this route when G5-51 is configured for combustion-air or clean-air supply.

View Boiler FD Fans →
Boiler Induced Draft Fans

Use this route when Y5-51 is configured for flue-gas extraction and negative-pressure support.

View Boiler ID Fans →
Boiler Draft System Pages

Review complete forced-draft and induced-draft routes before final fan positioning.

FD System → ID System →
G/Y4-73 Boiler Centrifugal Fan

Compare another clean-air and flue-gas boiler fan family with separate G and Y directions.

View G/Y4-73 →
GY6-41 Industrial Boiler Fan

Review a smaller industrial boiler blower and induced-draft direction for medium-duty systems.

View GY6-41 →
GY6-51 Large-Capacity Draft Fan

Review a larger-capacity boiler draft series for higher airflow, pressure and motor power.

View GY6-51 →
RFQ Support

Get a GY5-51 Boiler Fan Quote

Send boiler capacity, fan position, airflow, pressure, temperature, dust concentration, outlet direction, rotation, voltage and site layout.

QIYUE FAN CO., LTD.
Boiler Forced Draft and Induced Draft Fan Manufacturer | Fan Position and Operating-Point Support
Tel / WeChat / WhatsApp: +86 15653305981   |   Email: sales@qiyuefan.com

Hot Tags: gy5-51 boiler centrifugal forced draft and induced draft fan, China gy5-51 boiler centrifugal forced draft and induced draft fan manufacturers, suppliers, factory