QIYUE FAN manufactures industrial centrifugal fans for factory ventilation, dust collection, boiler draft, furnace blowing, forced air supply, material handling and high-resistance airflow systems. Selection starts from airflow, pressure, medium, temperature, dust condition and system resistance before the fan series and mechanical configuration are confirmed.

Request Centrifugal Fan Selection → Send Fan Requirements →
Selection Starts Here
01 · Application
Ventilation · dust · boiler · process air
02 · Airflow & Pressure
Required duty point and system resistance
03 · Medium Condition
Temperature · dust · gas composition
04 · Configuration
Drive · rotation · outlet · motor
01 · Airflow Principle

How an Industrial Centrifugal Fan Moves Air

Air enters near the center of the rotating impeller, gains velocity and pressure, and is discharged through the volute outlet. This makes centrifugal fans suitable for systems where airflow must overcome ducts, filters, dust collectors, boilers or process equipment resistance.

01
Air Inlet
Air enters near the impeller center.
02
Impeller Rotation
The wheel adds velocity to the airflow.
03
Pressure Increase
Velocity is converted into useful pressure.
04
Duct Outlet
Pressurized airflow enters the system.
02 · Working Condition

Choose a Centrifugal Fan by System Duty

Different series cover different airflow, pressure and operating conditions. Begin with the duty, then compare the appropriate fan family.

General Ventilation
4-72 / 4-68 / 4-79
Factories, workshops, warehouses, buildings and ordinary ducted air supply or exhaust.
Large Air Volume
4-2×72 Double Inlet
Centralized ventilation, large duct systems, process cooling and double-inlet air handling.
High Pressure
8-09 / 9-12 / 9-19 / 9-26 / 10-16
Furnace blowing, forced air, conveying and higher-resistance process systems.
Boiler / Gas Duty
Y6-30 / MJG
Boiler induced draft or project-selected industrial gas pressurizing applications.
03 · Complete Product Entry

Centrifugal Fan Product & Series Entry

The complete centrifugal fan entry below includes the current product pages and the high-pressure comparison hub already published on QIYUE FAN.

 
General Ventilation
4-72 Centrifugal Ventilation Fan
Factory ventilation, workshop exhaust and ordinary clean-air systems.
View 4-72 →
 
Large Ventilation Range
4-68 Centrifugal Ventilation Fan
General air supply and exhaust with broad model and drive options.
View 4-68 →
 
Indoor Air Exchange
4-79 Centrifugal Ventilation Fan
Indoor air supply and exhaust for factories, workshops and buildings.
View 4-79 →
 
Double Inlet
4-2×72 Double Inlet Fan
Large-volume centralized ventilation and process air handling.
View 4-2×72 →
 
Furnace Blowing
8-09 High Pressure Fan
High-pressure furnace blowing and industrial gas conveying duty.
View 8-09 →
 
High Resistance
9-12 High Pressure Fan
Long ducts, equipment resistance and high-pressure process air delivery.
View 9-12 →
 
Pressure-First Duty
9-19 High Pressure Fan
Forced air, conveying and high-resistance industrial airflow systems.
View 9-19 →
 
Higher Airflow + Pressure
9-26 High Pressure Fan
Heavy-duty forced airflow, conveying and high-resistance systems.
View 9-26 →
 
Heavy-Duty High Pressure
10-16 High Pressure Fan
Furnace air supply, forced ventilation and material conveying.
View 10-16 →
 
Boiler Induced Draft
Y6-30 Boiler ID Fan
Small and medium boiler flue gas extraction and negative-pressure support.
View Y6-30 →
 
Gas Pressurizing
MJG Gas Booster Fan
Coal gas, coke oven gas and project-selected industrial gas boosting.
View MJG →
 
Series Comparison Hub
High Pressure Centrifugal Fans
Compare 8-09, 9-12, 9-19 and 9-26 before final model selection.
Compare Series →
04 · Engineering Basics

Technical Checks Before Final Fan Selection

Use these guides to connect the operating point with impeller geometry, drive arrangement, speed, fan curve and installation details.

Fan Arrangement Types
Compare Arrangement 1, 3, 4, 7, 8, 9, 10 and SWSI / DWDI layouts.
Centrifugal Fan Blade Types
Forward-curved, radial and backward-curved impeller families.
Fan Laws
Understand how speed, diameter and density affect airflow, pressure and power.
Fan Performance Curve
Match airflow, pressure, absorbed power and duty point on the tested curve.
Motor Poles & Fan RPM
Review 50Hz / 60Hz speed, motor slip, VFD operation and fan RPM.
Rotation & Outlet Angle
Confirm CW/CCW rotation, outlet angle and installation direction before production.
05 · Selection Path

Centrifugal Fan Selection Is Not Model-Number Matching

01
Application
Ventilation · dust · boiler · process
02
Airflow
Required m³/h at the duty point
03
Pressure
Static / total pressure and resistance
04
Fan Series
Model family + mechanical configuration
Medium composition, temperature, dust condition, installation direction, motor requirement and actual duct resistance must also be checked before quotation.
06 · Typical Applications

Where Industrial Centrifugal Fans Are Used

Workshop Ventilation
Factory exhaust, air exchange and production-building ventilation.
View Application →
Dust Collection
Collectors, baghouse systems, grinding dust and process exhaust.
View Application →
Forced Draft
Combustion air, equipment air delivery and industrial forced airflow.
View Application →
Pneumatic Conveying
Powder, particle and bulk-material conveying air systems.
View Application →
Boiler Draft
Flue gas extraction, induced draft and negative-pressure control.
View Application →
Furnace Exhaust
Furnace, kiln and reviewed high-temperature process exhaust.
View Application →
07 · FAQ

Centrifugal Fan Questions Buyers Often Ask

What is a centrifugal fan used for?
It moves air or industrial gas through systems where duct, filter or process resistance must be overcome, including ventilation, dust collection, boiler draft and process air delivery.
How do I choose a centrifugal fan?
Confirm application, airflow, static or total pressure, temperature, gas or dust condition, duct resistance, voltage, installation direction and quantity before selecting the series.
What is the difference between 4-72, 4-68, 9-19 and 9-26?
4-72 and 4-68 are general ventilation directions. 9-19 and 9-26 are reviewed for higher-pressure forced-air, conveying and high-resistance duties.
Which centrifugal fan is suitable for dust collection?
It depends on dust loading, collector resistance, particle condition and fan position. Dirty-side and clean-side fan selection should be reviewed differently.
Which fan is suitable for boiler induced draft?
Check flue gas temperature, dust content, total resistance and operating hours. Y6-30 and other boiler fan series can then be reviewed according to actual boiler duty.
What information is needed for quotation?
Application, airflow, pressure, temperature, medium, dust condition, duct layout, power supply, rotation, outlet direction, quantity and destination are the key inputs.
Centrifugal Fan Selection & Quotation

Send the Operating Point Before Choosing a Fan Series

Send the application, airflow, pressure, temperature, medium condition, duct resistance, voltage, rotation, outlet direction, quantity and destination. QIYUE FAN can review the suitable centrifugal fan family and configuration.

Request Fan Selection → Send Fan Requirements →
Additional Platform Product Listing
The automatic product list below is supplemental. Use the complete 12-card product entry above for the primary centrifugal fan selection path.
  • 10-16 High Pressure Centrifugal Fan
    The 10-16 high pressure centrifugal fan is designed for industrial forced ventilation, sulfuric acid furnace bottom ventilation, forging furnace air supply and material conveying systems. It is...
    read more
  • MJG Gas Booster Fan For Coal Gas Pressurizing
    MJG Gas Booster Fan for Coal Gas Pressurizing is a heavy-duty centrifugal blower designed for coal gas, coke oven gas, blast furnace gas, converter gas, biogas, methane and other industrial gas...
    read more
  • High Pressure Centrifugal Fans
    High Pressure Centrifugal Fans is a QIYUE FAN product series selection page for comparing 8-09, 9-12, 9-19 and 9-26 fan directions before model confirmation. This page helps buyers start from...
    read more
  • Y6-30 Boiler Induced Draft Fan
    The Y6-30 boiler induced draft fan is designed for extracting boiler flue gas and maintaining stable negative pressure in industrial boiler systems. It can be supplied with C-type or D-type drive,...
    read more
  • 4-2×72 Double Inlet Centrifugal Fan
    The 4-2×72 double inlet centrifugal fan is designed for large-volume industrial ventilation and centralized air handling systems. Its double-inlet structure allows air to enter both sides of the...
    read more
  • 4-79 Centrifugal Ventilation Fan
    4-79 Centrifugal Ventilation Fan is designed for indoor air supply and exhaust ventilation in general factories, workshops and large buildings. It is suitable for conveying clean air or...
    read more
  • 9-12 High Pressure Centrifugal Fan
    9-12 High Pressure Centrifugal Fan is designed for cupola furnace blowing, melting furnace air supply, forging furnace ventilation and high pressure industrial air supply. It is suitable for...
    read more
  • 8-09 High Pressure Centrifugal Fan
    8-09 High Pressure Centrifugal Fan is designed for cupola furnace blowing, melting furnace air supply, forging furnace ventilation and industrial gas conveying.
    It is suitable for...
    read more
  • 9-26 High Pressure Centrifugal Fan
    9-26 high pressure centrifugal fan for heavy-duty forced airflow, industrial furnace air supply, dust collection systems, material conveying and equipment ventilation. Suitable for higher pressure...
    read more
  • 9-19 High Pressure Centrifugal Fan
    9-19 high pressure centrifugal fan for forced air supply, boiler draft, combustion support, material conveying and industrial equipment airflow systems. Designed for higher pressure airflow...
    read more
  • 4-72 Centrifugal Ventilation Fan
    4-72 centrifugal ventilation fan for factory ventilation, workshop exhaust, air supply and general industrial airflow systems. Suitable for clean air or non-corrosive gas conveying under ordinary...
    read more
  • 4-68 Centrifugal Ventilation Fan
    4-68 centrifugal ventilation fan for factories, workshops, warehouses, large buildings and general industrial air supply or exhaust systems. Suitable for clean air or non-corrosive gas under...
    read more

With abundant experience, we are one of the most reliable centrifugal fans manufacturers and suppliers in China. Please feel free to wholesale high quality centrifugal fans made in China here from our factory. We also accept customized orders.

Send Inquiry