10-18 High-Pressure Centrifugal Fan

10-18 High-Pressure Centrifugal Fan

The 10-18 high-pressure centrifugal fan is designed for forced ventilation, furnace air supply and industrial air-moving duties requiring comparatively high pressure.
The published series covers sizes 4A through 22.4F with A, D and F arrangements, airflow from 852 to 109,890 m³/h and total pressure up to approximately 22,142 Pa.
Typical applications include cupola furnaces, combustion air systems, industrial furnaces and pneumatic conveying. Standard conveyed-medium temperature is generally not above 80°C, with dust content not exceeding 150 mg/m³.
Send Inquiry
Description
High-Pressure Industrial Centrifugal Fan
10-18 High-Pressure Centrifugal Fan
 

The 10-18 high-pressure centrifugal fan is designed for forced ventilation, furnace air supply and industrial air-moving duties requiring comparatively high pressure. The published series covers sizes 4A through 22.4F with A, D and F arrangements.

Published performance extends from 852 to 109,890 m³/h with total pressure up to 22,142 Pa. Fan selection should be based on the required operating point, gas conditions and system resistance.

 
10-18 high-pressure centrifugal fan for industrial furnace ventilation and process air
Sizes
4A–22.4F
Airflow
Up to 109,890
Pressure
Up to 22,142 Pa
Temperature
≤80°C
Model Range
4A–22.4F
Airflow
852–109,890
m³/h
Total Pressure
3,328–22,142
Pa
Motor Power
3–850
kW
Efficiency Data
66.5–73.8%
 
Published Operating Envelope

High Pressure Across a Wide Model Range

The 10-18 series extends from compact 4A direct-drive configurations to large 22.4F configurations. Published rotational speeds include 730, 960, 1450 and 2900 r/min depending on fan size.

Each fan size contains several published duty points. The minimum and maximum values below summarize the original performance tables and are intended for preliminary model screening rather than final fan selection.

01
16 Published Sizes
4A through 22.4F.
02
A / D / F Arrangements
Arrangement suffixes follow the original manufacturer performance tables.
03
Up to 22.1 kPa
High-pressure operating points for industrial air-moving duties.
04
Up to 109,890 m³/h
Large F-arrangement sizes extend the airflow range substantially.
 
Model & Arrangement

A, D and F Configurations

A ARRANGEMENT
4A–6.3A
4A
4.5A
5A
5.6A
6.3A
D ARRANGEMENT
7.1D–16D
7.1D / 8D / 9D / 10D
11.2D / 12.5D / 14D / 16D
F ARRANGEMENT
18F–22.4F
18F
20F
22.4F
Important: The arrangement suffix is part of the original model designation. Final drive arrangement, motor configuration and installation dimensions should be confirmed for the selected duty point before production.
 
Performance Data

10-18 Performance Range by Fan Size

The ranges below are consolidated from the original 10-18 performance tables. Where more than one rotational speed is listed for the same fan size, the range includes all published operating points for that model.

Model
Speed r/min
Airflow m³/h
Total Pressure Pa
Motor kW
Arrangement
4A
2900
852–1,890
3,872–4,374
3–4
A
4.5A
2900
1,213–2,691
4,902–5,536
4–7.5
A
5A
2900
1,661–3,692
6,052–6,834
7.5–11
A
5.6A
2900
2,337–5,187
7,592–8,573
15–18.5
A
6.3A
2900
3,328–7,385
9,609–10,850
22–30
A
7.1D
2900
4,763–10,571
12,204–13,780
45–75
D
8D
1450 / 2900
3,407–15,122
3,874–17,495
11–110
D
9D
1450
4,851–10,766
4,902–5,536
18.5–30
D
10D
1450
6,654–14,768
6,052–6,834
30–45
D
11.2D
960 / 1450
6,189–20,748
3,328–8,573
15–75
D
12.5D
960 / 1450
8,604–28,843
4,145–10,678
30–132
D
14D
960 / 1450
12,089–40,522
5,200–13,395
45–250
D
16D
960 / 1450
18,045–60,488
6,792–17,495
110–410
D
18F
960 / 1450
25,692–86,125
8,596–22,142
185–850
F
20F
730 / 960
28,800–78,218
6,136–11,982
130–380
F
22.4F
960
49,514–109,890
13,311–15,030
520–680
F
Performance reference conditions: temperature 20°C, air density 1.2 kg/m³ and atmospheric pressure 101,325 Pa. Published efficiency values across the listed duty points are approximately 66.5%–73.8%.
 
Technical Drawing

Outline & Installation Reference

The technical drawing shows the casing, motor position, inlet and outlet interfaces, mounting arrangement and dimensional references used for installation.

The original manual uses shared installation-reference drawings for the 10-18, 9-18 and 9-16 high-pressure centrifugal fan families. Final project dimensions must therefore be confirmed for the selected 10-18 model before fabrication or site installation.

10-18 9-18 9-16 high-pressure centrifugal fan outline and installation dimensions
01
Inlet Dimensions
Check inlet diameter, flange and bolt pattern against the final drawing.
02
Outlet Dimensions
Rectangular discharge interface dimensions vary by fan size.
03
Foundation
Foundation dimensions and anchor-bolt specifications must match the selected model.
04
Final Confirmation
Production dimensions should be confirmed after duty-point selection.
 
Discharge Orientation

Multiple Outlet Directions

The installation reference includes multiple right-hand discharge positions. Final orientation should be specified when placing the order so the casing and project interface can be checked together.

01
Right 0°
02
Right 45°
03
Right 90°
04
Right 135°
05
Right 180°
06
Right 225°
 
Applications

High-Pressure Air Supply & Material Conveying

 

Cupola Furnaces

Forced-air applications associated with medium and small cupola furnace systems.

 

Combustion Furnaces

High-pressure combustion-air and forced-ventilation duties.

 

Oil-Fired Furnace Air

Positive-pressure oil-fired furnace ventilation where the required duty falls within the published range.

 

Material & Grain Conveying

Pneumatic conveying applications subject to gas and material compatibility checks.

 
Conveyed Medium

Standard Gas Conditions

Temperature
≤80°C
Standard medium temperature limit stated in the original manual.
Dust Content
≤150 mg/m³
Maximum dust-content reference in the original product description.
Gas Compatibility
Non-Corrosive
Standard construction is intended for air or non-corrosive gases.
Material Condition
Non-Sticky
The conveyed gas should not contain sticky material under the standard application description.
Standard application description specifies gases that are non-corrosive, non-spontaneously combustible and non-flammable. For unusual gas composition, elevated temperature, explosive atmosphere or corrosive service, provide the actual medium data before selection.
 
Fan Selection

Select the 10-18 by Actual Duty Point

The same fan size may contain several published operating points, and some models are listed at more than one rotational speed. Selection should therefore start with the required airflow and pressure rather than model diameter alone.

Required airflow (m³/h)
Required total or static pressure (Pa)
Gas type and composition
Operating gas temperature
Dust or particle concentration
Site altitude or gas density, if relevant
System resistance or duct information
Voltage / frequency / phase
Required discharge direction
Existing fan data and dimensions for replacement projects
Quantity and destination country
 
FAQ

10-18 High-Pressure Centrifugal Fan FAQ

01

What is the airflow range of the 10-18 fan?

Across the published 4A–22.4F data, airflow ranges from approximately 852 to 109,890 m³/h.

02

What is the maximum published total pressure?

The highest operating point shown in the supplied 10-18 performance tables is approximately 22,142 Pa.

03

Which fan sizes are available?

Published sizes include 4A, 4.5A, 5A, 5.6A, 6.3A, 7.1D, 8D, 9D, 10D, 11.2D, 12.5D, 14D, 16D, 18F, 20F and 22.4F.

04

What gas temperature can the standard fan handle?

The original product description specifies a standard medium temperature generally not exceeding 80°C.

05

What is the maximum dust-content reference?

The manual specifies dust content not greater than 150 mg/m³ for the standard application.

06

Can different discharge directions be supplied?

The installation reference includes Right 0°, 45°, 90°, 135°, 180° and 225° positions. Confirm the required orientation with the RFQ.

07

Can QIYUE FAN match project voltage and frequency?

Motor configuration can be reviewed according to the selected operating point and project voltage, frequency and phase requirements.

08

Can the 10-18 be used for an existing fan replacement?

Yes, subject to duty-point and interface review. Send the existing nameplate, airflow, pressure, speed, motor data, rotation and available installation dimensions.

10-18 Fan Selection

Send Your Airflow & Pressure Requirement

QIYUE FAN can review the model size, rotational speed, motor configuration and outlet direction according to your project operating conditions.

QIYUE FAN
 
10-18 High-Pressure Centrifugal Fan Manufacturer
Tel / WeChat / WhatsApp: +86 15653305981   |   Email: sales@qiyuefan.com

Hot Tags: 10-18 high-pressure centrifugal fan, China 10-18 high-pressure centrifugal fan manufacturers, suppliers, factory