High-Pressure Centrifugal Fans
QIYUE FAN · HIGH-PRESSURE INDUSTRIAL AIRFLOW
High-Pressure Industrial Centrifugal Fan Series
Commercial product family covering 13 high-pressure centrifugal fan series for process air, forced draft, furnace blowing, high-resistance duct systems and reviewed conveying duties. Browse the product matrix here; use the dedicated High-Pressure Fan Selection Guide when the model is not yet confirmed.
PRODUCT FAMILY SCOPE
Complete Product Family for High-Pressure Industrial Airflow
This category groups the complete high-pressure centrifugal fan product range. Use it to compare available series, duty positioning and individual product pages before moving into detailed engineering selection.
Need to choose between series?
Use the dedicated High-Pressure Centrifugal Fan Selection Guide → for resistance-first comparison, operating-point logic and model screening.
01 · PRODUCT RANGE
Browse the Complete High-Pressure Fan Series
Compare duty direction, reference performance range and product configuration, then open the individual series page for detailed performance, dimensions and project selection data.
High-Pressure Centrifugal Fan Series
Small Airflow · High Pressure
6-27 High-Pressure Centrifugal Fan
72–621 m³/h · 6,600–7,492 Pa. Compact direct-drive fan for concentrated process-air duties.
Process Air · Conveying
6-30 High-Pressure Process Air Fan
1,120–17,300 m³/h · 804–6,317 Pa. A / C arrangements for process air and reviewed conveying systems.
Furnace Blowing · High-Pressure Air
8-09 High Pressure Centrifugal Fan
Established furnace blowing and high-pressure industrial air-supply series.
High Resistance · Process Air
9-12 High Pressure Centrifugal Fan
High-resistance process-air and furnace-air direction for longer ducts and equipment losses.
Broad High-Pressure Range
9-16 High-Pressure Centrifugal Fan
Approx. 934–163,427 m³/h · 3.79–25.46 kPa. A / D / F arrangements for forced-air and furnace duties.
High Pressure · Multi-Size
9-18 High-Pressure Centrifugal Fan
Approx. 797–157,654 m³/h · 3,168–21,067 Pa. Broad A / D / F range for demanding industrial air systems.
Pressure-First · Forced Air
9-19 High Pressure Centrifugal Fan
Pressure-first forced-air and reviewed conveying duties with significant system resistance.
Higher Airflow + Pressure
9-26 High Pressure Centrifugal Fan
Higher-airflow, higher-pressure established series for heavy industrial air systems.
High Flow · High Resistance
9-28 I High-Pressure Centrifugal Fan
Approx. 2,198–294,702 m³/h · 2,972–17,694 Pa. For forced draft, kiln, furnace and large-flow process air.
Compact Extreme Pressure
10-08-31 High-Pressure Centrifugal Fan
Approx. 940–4,405 m³/h · pressure up to about 37.84 kPa. Compact belt-driven extreme-pressure direction.
Heavy-Duty Process Air
10-16 High Pressure Centrifugal Fan
Heavy-duty high-pressure series for furnace air, forced ventilation and reviewed conveying duties.
Heavy-Duty High Pressure
10-18 High-Pressure Centrifugal Fan
852–109,890 m³/h · up to approx. 22,142 Pa. A / D / F family for furnace and industrial forced-air systems.
Very High Pressure
10-24 High-Pressure Centrifugal Fan
Approx. 7,210–20,178 m³/h · 11,920–19,964 Pa. High-speed series for furnace FD and restrictive process air.
02 · ENGINEERING SELECTION
Not Sure Which High-Pressure Series Fits the Duty?
This category page is the commercial product matrix. Detailed engineering selection is handled separately so the product family and selection guide do not compete for the same role. Use the selection hub to compare resistance source, airflow, pressure, medium condition and operating point before confirming a model.
03 · APPLICATION PATHS
Common High-Resistance Industrial Systems
Application type identifies the starting direction. The final product still needs to match the required airflow, pressure, system resistance and medium condition.
Forced Draft
Combustion air, furnace air and industrial forced-air systems.
View Application →Pneumatic Conveying
Higher-pressure airflow for reviewed conveying systems.
View Application →Dust Collection
High-resistance collector and clean-side extraction systems.
View Application →High-Temperature Exhaust
Hot process gas and furnace / kiln exhaust duties where temperature and medium conditions require a dedicated selection path.
View Application →04 · EXISTING FAN REPLACEMENT
Replacing an Existing High-Pressure Fan?
When the original airflow or pressure is missing, remaining mechanical information can still help reconstruct the likely duty. Do not replace a fan from motor power alone.
Fan nameplate and existing model
Motor power, RPM, voltage and frequency
Inlet and outlet dimensions
Impeller diameter if measurable
Rotation and discharge direction
Existing drawings, photos or performance curve
OPERATING BOUNDARY
High Pressure Does Not Mean Every Difficult Duty
Special medium conditions can require another fan family, material or mechanical construction even when the pressure requirement is high.
Corrosive gas: review corrosion-resistant materials and construction.
Explosion hazard: review required explosion-proof configuration and electrical specification.
High temperature: review boiler, furnace or high-temperature construction.
Abrasive dust: review wear protection and fan position.
Very high-pressure conveying: a different blower or air-source solution may be required.
05 · RFQ
Send the Duty Point or Existing Fan Data
QIYUE FAN can review the suitable high-pressure series according to airflow, pressure, system resistance, medium condition, drive arrangement and installation requirements.
RECOMMENDED RFQ DATA
Airflow · Pressure · System Resistance · Temperature · Medium / Dust · Voltage / Frequency · Rotation / Outlet · Quantity / Destination
Send Inquiry
