G/Y4-73 Boiler Centrifugal Forced Draft and Induced Draft Fan

G/Y4-73 Boiler Centrifugal Forced Draft and Induced Draft Fan

G/Y4-73 boiler centrifugal fan for boiler forced draft, induced draft, flue gas exhaust, dust removal systems and industrial boiler ventilation. G4-73 is used for boiler air supply, while Y4-73 is used for boiler flue gas exhaust after dust removal.
Send Inquiry
Description
Boiler Air-Path Fan Selection

G/Y4-73
Boiler Centrifugal Fan

 

G/Y4-73 is selected according to the fan position in the boiler air path. G4-73 works on the clean-air side to supply combustion air, while Y4-73 works on the flue-gas side to support induced draft after combustion.

The series is suitable for 2–670 t/h steam boiler systems. Configuration should be confirmed according to airflow, pressure, medium temperature, dust condition, corrosion risk and the site duct layout.

Carbon steel, 304 stainless steel and 316L stainless steel directions can be discussed according to temperature and corrosion requirements.

G Y4-73 boiler centrifugal fan for clean-air supply and flue-gas induced draft systems
Clean-Air Side
G4-73
Flue-Gas Side
Y4-73
Temperature
Air ≤80°C
Flue gas ≤250°C
Model Range
No.8D–No.28D
D-type drive; rotation and outlet angle matched to the site duct layout.
Boiler Range
2–670 t/h
For large steam boiler air-supply and flue-gas systems.
Clean-Air Duty
G4-73
Combustion-air supply before the boiler or furnace.
Flue-Gas Duty
Y4-73
Induced-draft support after combustion and dust removal.
Material Direction
CS / 304 / 316L
Confirmed according to temperature and corrosion risk.
Product Positioning

Read the Boiler Air Path Before Choosing the Fan

In a boiler room, the first selection step is to confirm where the fan works in the air path. A fan installed before combustion usually handles clean air. A fan installed after combustion must handle temperature, dust, flue-gas resistance and possible corrosion.

G4-73 and Y4-73 should therefore not be treated as the same working condition. Even when airflow and pressure appear similar, the medium condition may require different material, motor, bearing, casing and maintenance arrangements.

For flue-gas applications, a dust-removal device should be arranged before the fan. In common power-plant conditions, dust-removal efficiency is generally expected to be no less than 85%, helping reduce impeller wear and casing abrasion.
Boiler Air-Path Logic

Four Checks Before Model Confirmation

STEP 01
Locate the Fan Position

Confirm whether the fan works before combustion-air entry or after flue gas leaves the boiler.

STEP 02
Check the Medium

Clean air, hot smoke, dust concentration and corrosive components change the configuration direction.

STEP 03
Match System Resistance

Include boiler resistance, duct loss, dust-collector resistance, dampers and chimney conditions.

STEP 04
Confirm Material

Carbon steel, 304 stainless steel or 316L stainless steel should follow the actual duty.

G4-73 vs Y4-73

Clean-Air Side and Flue-Gas Side Comparison

Selection Point G4-73 Clean-Air Side Y4-73 Flue-Gas Side What to Confirm
Medium Clean air Smoke / flue gas Dust, temperature and corrosive components
Temperature ≤80°C ≤250°C Whether a high-temperature configuration is required
System Load Air-supply resistance Boiler, collector and flue resistance Actual pressure loss across the complete system
Material Usually simpler to configure May require corrosion-resistant material Carbon steel / 304 / 316L direction
Structure and Configuration

Main Fan Structure and Site Data

Single-Inlet Centrifugal Structure

Single-inlet centrifugal models cover the main range from No.8D to No.28D.

D-Type Transmission

Elastic coupling transmission supports stable operation in large boiler systems.

Rotation and Outlet Direction

Left-hand or right-hand rotation and the outlet angle should match the site duct direction.

Main Components

Impeller, casing, inlet, regulating device and transmission parts form the main fan unit.

G4-73 Performance Direction

G4-73 Clean-Air Side Performance Data

The following G4-73 data is for preliminary clean-air-side review. Final configuration should be checked against boiler capacity, required airflow, total pressure and motor standard.

Model Speed r/min No. Airflow m³/h Total Pressure Pa Motor Model Power kW
G4-73 No.8D 1450 1 16156–30993 2104–1400 Y180M-4 18.5
G4-73 No.9D 1450 1 23003–32079 2668–2559 Y200L-4 30
G4-73 No.9D 1450 2 35052–44128 2440–1775 Y225S-4 37
G4-73 No.10D 1450 1 31554–60533 3301–2194 Y250M-4 55
G4-73 No.11D 1450 1 41999–47427 4003–3986 Y280S-4 75
Larger G4-73 models No.12D, No.14D, No.16D, No.18D and No.20D are available for higher-airflow clean-air-side boiler systems.
Y4-73 Performance Direction

Y4-73 Flue-Gas Side Performance Data

The following Y4-73 data is for preliminary flue-gas-side review. Before quotation, confirm smoke temperature, collector resistance, dust condition and corrosion risk.

Model Speed r/min No. Airflow m³/h Total Pressure Pa Motor Model Power kW
Y4-73 No.8D 1450 1 16156–18244 1303–1298 Y160M-4 11
Y4-73 No.8D 1450 2 20442–30993 1284–868 Y160L-4 15
Y4-73 No.9D 1450 1 23003–32079 1651–1584 Y180L-4 22
Y4-73 No.9D 1450 2 35052–44128 1511–1100 Y200L-4 30
Y4-73 No.10D 1450 1 31554–44004 2041–1959 Y225S-4 37
Larger Y4-73 models No.11D, No.12D, No.14D, No.16D, No.18D and No.20D are available for larger flue-gas-side systems.
Quotation Data

Information Needed Before Quotation

01
Fan Position

Confirm clean-air side or flue-gas side before choosing G4-73 or Y4-73.

02
System Resistance

Include boiler, duct, dust collector, damper and chimney resistance.

03
Working Temperature

Temperature affects material, motor arrangement and bearing configuration.

04
Material Requirement

Confirm carbon steel, 304 stainless steel or 316L stainless steel direction.

Related Selection Paths

Continue from G/Y4-73 to Product Family, System and Related Models

Use the aggregation and system pages to confirm the correct clean-air or flue-gas direction. Specific product pages remain available for direct model comparison.

Boiler Forced Draft Fans

Compare G4-73 with other combustion-air and clean-air boiler fan directions.

View Boiler FD Fans →
Boiler Induced Draft Fans

Compare Y4-73 with other flue-gas extraction and negative-pressure directions.

View Boiler ID Fans →
Industrial Forced Draft Fan System

Review the complete combustion-air route, resistance sources and control requirements.

View FD System →
Boiler Induced Draft System

Review the flue-gas route, collector resistance, furnace pressure and chimney discharge.

View ID System →
GY5-51 Boiler Draft Fan

Compare another boiler forced/induced draft series for steam boiler and fluidized-bed duty.

View GY5-51 →
GY6-41 Industrial Boiler Fan

Review a boiler blower and induced-draft direction for small and medium industrial boilers.

View GY6-41 →
RFQ Support

Get a G/Y4-73 Boiler Fan Quote

Send the fan position, airflow, pressure, temperature, medium, dust condition, material requirement, outlet direction, voltage and quantity.