Y5-47 Boiler Centrifugal Induced Draft Fan

Y5-47 Boiler Centrifugal Induced Draft Fan

Y5-47 boiler centrifugal induced draft fan for industrial boiler flue gas exhaust, smoke and dust removal systems, boiler ventilation and induced draft applications. Suitable for boiler systems after dust removal under confirmed gas temperature and dust content conditions. Model selection can be reviewed according to airflow, pressure, gas temperature, medium condition, motor power and installation direction.
Send Inquiry
Description
Standard Boiler Room Induced Draft Fan
Y5-47 Boiler
Induced Draft Fan
 

The Y5-47 boiler induced draft fan is used for standard industrial boiler flue-gas exhaust, smoke discharge and negative-pressure support after dust-removal equipment.

It is commonly reviewed for 1–20 t/h industrial boilers under confirmed inlet conditions. Normal working temperature should not exceed 250°C, and efficiency can reach 90.5% at suitable operating points.

Final selection should include boiler capacity, airflow, total pressure, collector resistance, gas temperature, dust condition, outlet angle and rotation direction.

Y5-47 boiler induced draft fan for standard industrial boiler flue gas exhaust after dust removal
Boiler Capacity
1–20 t/h
Temperature
≤250°C
Pressure Range
990–3854 Pa
Motor Power
3–90 kW
Single-suction boiler ID fan; rotation and outlet angle matched to the boiler-room duct layout.
Boiler Capacity
1–20 t/h
Standard industrial boiler-room induced-draft duty.
Model Sizes
4C–12.4D
Matched by airflow, pressure and installation layout.
Efficiency
Up to 90.5%
At suitable duty points and confirmed operating conditions.
Selection Basis
Complete Flue Route
Collector, duct, damper and chimney loss are included.
Product Positioning

Induced Draft Fan for Regular Boiler Flue-Gas Exhaust

Y5-47 is positioned for standard boiler induced-draft duty rather than extreme kiln exhaust or very large boiler systems. It is commonly used where stable flue-gas extraction, negative-pressure support and practical daily operation are required.

The fan is suitable for industrial boilers burning different coal types and equipped with smoke-removal or dust-collection devices. The resistance of the treatment equipment, flue duct and chimney route should be included when total pressure is confirmed.

Before quotation, QIYUE FAN reviews boiler capacity, flue-gas volume, total pressure, collector resistance, temperature, dust content, outlet angle and rotation direction.
Boiler Exhaust Route

Y5-47 Works After Boiler and Dust-Removal Resistance

The correct operating point should be based on the complete flue-gas route rather than the fan alone.

01
Boiler Furnace

Flue gas is generated during boiler combustion.

02
Dust Collector

Dust-removal equipment creates additional pressure loss.

03
Y5-47 ID Fan

Provides induced draft and supports negative furnace pressure.

04
Chimney Route

Discharge direction and chimney resistance complete the pressure calculation.

Selection Review

Confirm Boiler Draft Conditions Before Model Selection

Typical Suitable Direction
1–20 t/h industrial boiler systems
Boiler flue-gas exhaust after dust removal
Routine boiler-room induced draft
Smoke and dust-removal support
Negative-pressure support for boiler operation
Must Be Confirmed
Boiler capacity and flue-gas volume
Total pressure and duct resistance
Dust-collector resistance
Flue-gas temperature and dust content
Outlet angle, rotation and motor standard
Fan Configuration

Y5-47 Structure and Installation Data

ITEM
CONFIGURATION
Inlet Type
Single-suction induced draft fan
Main Sizes
No.4, No.5, No.6, No.8, No.9, No.12 and No.12.4
Outlet Angles
0°, 90° and 180° according to the boiler-room duct layout
Rotation
Left-hand or right-hand rotation viewed from the transmission side
Main Components
Impeller, casing, inlet, transmission part and regulating door
Performance Data

Y5-47 Boiler Induced Draft Fan Performance Reference

The following data is for preliminary selection. Final model selection should be confirmed according to boiler capacity, flue-gas volume, total pressure, collector resistance, temperature and installation layout.

MODEL
SPEED
PRESSURE
AIRFLOW
POWER
MOTOR
4C
2900
990–1451 Pa
2750–5060 m³/h
3 kW
Y100L-2
4C
3300
1285–1873 Pa
3130–5750 m³/h
4 kW
Y112M-2
5C
2900
1549–2265 Pa
5360–9870 m³/h
7.5 kW
Y132S2-2
6C
2850
2148–3148 Pa
11300–16760 m³/h
18.5 kW
Y160L-2
8C
1820
1726–2501 Pa
17080–25360 m³/h
22 kW
Y180L-4
9C
1740
2001–2922 Pa
18780–34550 m³/h
37 kW
Y225S-4
12D
1450
2471–3609 Pa
37100–68250 m³/h
75 kW
Y280S-4
12.4D
1450
2638–3854 Pa
40940–75330 m³/h
90 kW
Y280M-4
Normal working temperature should not exceed 250°C. Dust-collector resistance should be included in total-pressure calculation.
Application Scenarios

Typical Y5-47 Boiler Fan Applications

Standard Boiler-Room Exhaust

For regular boiler-room flue-gas discharge and induced-draft support.

Boiler After Dust Removal

For systems with smoke-removal and dust-collection equipment before the fan.

Negative-Pressure Support

Supports stable boiler draft and continuous flue-gas movement.

Coal-Fired Boiler Systems

For industrial boilers burning different coal types under confirmed inlet conditions.

Routine Heating Plants

For normal industrial heating conditions where dependable daily operation matters.

Replacement Projects

Model comparison can start from the old nameplate, boiler capacity, pressure and outlet direction.

Related Selection Paths

Continue from Y5-47 to Product Family, System and Related Models

Use the aggregation and system pages for the wider boiler induced-draft route. Specific product pages remain available for direct model comparison.

Boiler Induced Draft Fans

Compare Y5-47 with other boiler flue-gas extraction and negative-pressure fan directions.

View Boiler ID Fans →
Boiler Induced Draft System

Review the complete flue-gas route, collector resistance, furnace pressure and chimney discharge.

View ID System →
Boiler Fan Selection Guide

Compare ID, FD and high-temperature duties and prepare the operating data required before quotation.

Read Selection Guide →
Y5-48 Boiler Induced Draft Fan

Compare a smoke-removal and dust-collection direction for stronger environmental-treatment resistance.

View Y5-48 →
Y8-39 / Y9-38 Boiler ID Fan

Review a higher-pressure direction for stronger boiler, kiln and furnace exhaust resistance.

View Y8-39 / Y9-38 →
GY6-51 Large-Capacity Draft Fan

Review a larger-capacity boiler draft direction for higher airflow and stronger system resistance.

View GY6-51 →
FAQ

FAQ About Y5-47 Boiler Induced Draft Fan

What is the Y5-47 fan used for?

It is used for standard industrial boiler flue-gas exhaust, smoke discharge, dust-removal support and negative-pressure control.

What boiler capacity does it usually support?

It is commonly reviewed for 1–20 t/h industrial boiler systems under matching inlet conditions.

What temperature can it handle?

Normal working temperature should not exceed 250°C. Higher-temperature duties require a separate review.

What data is needed before quotation?

Send boiler capacity, airflow, total pressure, collector resistance, temperature, dust content, outlet angle, rotation, voltage and quantity.

RFQ Support

Send Your Boiler Induced Draft Parameters

Share boiler capacity, airflow, total pressure, collector resistance, gas temperature, dust condition, outlet direction, rotation, voltage and quantity.

QIYUE FAN
 
SHANDONG QIYUE FAN CO., LTD.
Boiler Induced Draft Fan Manufacturer
Tel / WeChat / WhatsApp: +86 15653305981   |   Email: sales@qiyuefan.com

Hot Tags: y5-47 boiler centrifugal induced draft fan, China y5-47 boiler centrifugal induced draft fan manufacturers, suppliers, factory

Send Inquiry