Y5-47 Boiler Centrifugal Induced Draft Fan

Y5-47 Boiler Centrifugal Induced Draft Fan

Y5-47 boiler centrifugal induced draft fan for industrial boiler flue gas exhaust, smoke and dust removal systems, boiler ventilation and induced draft applications. Suitable for boiler systems after dust removal under confirmed gas temperature and dust content conditions. Model selection can be reviewed according to airflow, pressure, gas temperature, medium condition, motor power and installation direction.
Send Inquiry
Description
Standard Boiler Room Induced Draft Fan

Y5-47 Boiler Induced Draft Fan

 

The Y5-47 boiler induced draft fan is used for standard industrial boiler flue gas exhaust, smoke discharge and boiler negative pressure support after dust removal devices.

It is suitable for 1–20 t/h industrial boilers under confirmed inlet conditions, with working temperature normally not exceeding 250°C and efficiency up to 90.5% under suitable duty points.

Y5-47 boiler induced draft fan for industrial boiler flue gas exhaust after dust removal
Boiler Range
1-20 t/h
Temperature
≤250°C
Boiler Capacity
1-20 t/h
Standard industrial boiler room duty.
Model Sizes
4C-12.4D
Matched by airflow, pressure and site layout.
Pressure Range
990-3854
Pa reference range for ID fan selection.
Motor Power
3-90kW
Power confirmed by boiler exhaust duty.
Product Positioning

Induced Draft Fan for Regular Boiler Flue Gas Exhaust

Y5-47 is positioned for standard boiler induced draft duty rather than extreme kiln exhaust or very large boiler draft systems. It is commonly used in boiler rooms that need stable flue gas extraction, reliable negative pressure support and practical daily operation.

The fan is suitable for industrial boilers burning different coal types and equipped with smoke removal and dust collection devices. The resistance of the dust removal device, flue duct and chimney route should be included when confirming the total pressure.

Before quotation, QIYUE FAN reviews boiler capacity, flue gas volume, total pressure, gas temperature, dust content, dust collector resistance, outlet angle and rotation direction.

Boiler Exhaust Route

Y5-47 Works After Boiler and Dust Removal Resistance

A boiler induced draft fan should be selected by checking the whole flue gas route. The dust collector and duct system often decide how much pressure the fan must overcome.

01
Boiler Furnace

Flue gas is generated by boiler combustion.

02
Dust Collector

Dust removal device creates pressure loss.

03
Y5-47 ID Fan

Provides induced draft and negative pressure.

04
Chimney Route

Discharge direction and chimney resistance are checked.

Selection Review

Confirm Boiler Draft Conditions Before Model Selection

Typical Suitable Direction
1-20 t/h industrial boiler systems
Boiler flue gas exhaust after dust removal
Routine boiler room induced draft
Smoke and dust removal support
Negative pressure support for boiler operation
Must Be Confirmed
Boiler capacity and flue gas volume
Total pressure and duct resistance
Dust collector resistance
Flue gas temperature and dust content
Outlet angle, rotation and motor standard
Fan Configuration

Y5-47 Structure and Installation Data

Inlet Type
Single suction induced draft fan
Main Sizes
No.4, No.5, No.6, No.8, No.9, No.12 and No.12.4
Outlet Angles
0°, 90° and 180° according to boiler room duct layout
Rotation
Left-hand or right-hand rotation viewed from the transmission side
Main Components
Impeller, casing, inlet, transmission part and regulating door
Performance Data

Y5-47 Boiler Induced Draft Fan Performance Reference

The following table is for preliminary selection. Final model selection should be confirmed according to boiler capacity, flue gas volume, total pressure, dust collector resistance, temperature and installation layout.

Model Speed r/min Total Pressure Pa Airflow m³/h Power kW Motor Model
4C 2900 990-1451 2750-5060 3 Y100L-2
4C 3300 1285-1873 3130-5750 4 Y112M-2
5C 2900 1549-2265 5360-9870 7.5 Y132S2-2
6C 2850 2148-3148 11300-16760 18.5 Y160L-2
8C 1820 1726-2501 17080-25360 22 Y180L-4
9C 1740 2001-2922 18780-34550 37 Y225S-4
12D 1450 2471-3609 37100-68250 75 Y280S-4
12.4D 1450 2638-3854 40940-75330 90 Y280M-4

Note: The working temperature should not exceed 250°C under normal use. Dust collector resistance should be included in total pressure calculation.

Application Scenarios

Typical Y5-47 Boiler Fan Applications

Standard Boiler Room Exhaust

Used for regular boiler room flue gas discharge and induced draft support.

Boiler After Dust Removal

Selected when smoke removal and dust collection devices are installed before fan or in the exhaust line.

Negative Pressure Support

Helps maintain stable boiler draft and flue gas movement.

Coal-Fired Boiler Systems

Practical for industrial boilers burning different kinds of coal under suitable inlet conditions.

Routine Heating Plants

Used in normal industrial heating conditions where dependable daily operation matters.

Replacement Projects

Model comparison based on old fan nameplate, boiler capacity, pressure and installation direction.

FAQ

FAQ About Y5-47 Boiler Induced Draft Fan

What is the Y5-47 boiler induced draft fan used for?

It is used for standard industrial boiler flue gas exhaust, smoke discharge, dust removal support and negative pressure control in boiler rooms.

What boiler capacity does Y5-47 usually support?

It is commonly used for 1-20 t/h industrial boiler systems under matching inlet conditions.

What temperature can the Y5-47 fan handle?

The normal working temperature should not exceed 250°C. Higher temperature conditions should be reviewed separately before selection.

What information should I send before quotation?

Please send boiler capacity, required airflow, total pressure, dust collector resistance, flue gas temperature, dust content, outlet angle, rotation direction, voltage and quantity.

Send Your Boiler Induced Draft Parameters

Share boiler capacity, airflow, total pressure, dust collector resistance, flue gas temperature, dust content, outlet direction, rotation, voltage and quantity. QIYUE FAN will review whether the Y5-47 boiler induced draft fan fits your project.

QIYUE FAN CO., LTD.
Boiler Induced Draft Fan Manufacturer | Boiler Room Fan Selection Support
Tel / WeChat / WhatsApp: +86 15653305981   |   Email: sales@qiyuefan.com

Hot Tags: y5-47 boiler centrifugal induced draft fan, China y5-47 boiler centrifugal induced draft fan manufacturers, suppliers, factory