Boiler Induced Draft Fans

Boiler Induced Draft Fans

QIYUE boiler induced draft fan product family includes Y6-30, Y5-47, Y5-48, Y8-39/Y9-38, Y4-73 and GY series for boiler flue gas extraction, dust-removal resistance and negative-pressure control. Final selection is based on airflow, total pressure, gas temperature, dust condition and installation layout.
Send Inquiry
Description
QIYUE FAN · Boiler Product Family

Boiler Induced Draft Fans

Compare centrifugal ID fan models for boiler flue gas extraction, dust-removal resistance and stable negative-pressure operation. This page organizes QIYUE FAN product families by boiler scale, pressure demand and working condition.

Flue Gas Exhaust
Boiler Negative Pressure
Dust Collector Resistance
Multiple Boiler Fan Series
Send Boiler Parameters View ID Fan System Guide
Boiler Induced Draft Fan Family Including Y6-30 Y5-47 Y5-48 and Y8-39 Series
Product Page Positioning

Choose the Product Family Before Confirming the Exact Model

A boiler induced draft fan is selected from the complete exhaust duty-not from the model name or motor power alone. Use the cards below to identify a preliminary product direction, then confirm airflow, total pressure, gas temperature, dust condition, system resistance and installation arrangement.

01

Boiler and Fuel

Confirm boiler capacity, fuel type, operating load and combustion process.

02

Airflow and Pressure

Use the design airflow and total resistance at the required operating point.

03

Flue Gas Condition

Review continuous temperature, peak temperature, dust, moisture and corrosion risk.

04

Site Arrangement

Confirm drive type, rotation, outlet angle, foundation and duct connection.

Primary ID Fan Models

Boiler Induced Draft Fan Product Series

Use these four product entries to identify the initial boiler ID fan direction before confirming the operating point.

Y6-30 boiler induced draft fan for small industrial boiler systems
Compact Boiler ID Fan

Y6-30 Boiler Induced Draft Fan

A compact induced draft direction for small and medium industrial boilers, exhaust after dust removal and replacement projects.

Reference: 655–17,262 m³/h · 727–3,226 Pa · 0.75–22 kW.

View Y6-30 →
Y5-47 boiler induced draft fan for standard industrial boiler flue gas exhaust
Standard Boiler Room Duty

Y5-47 Boiler Induced Draft Fan

For regular industrial boiler flue gas exhaust and negative-pressure support after the dust-removal section.

Reference: 1–20 t/h boiler duty · up to 250°C under confirmed inlet conditions.

View Y5-47 →
Y5-48 boiler induced draft fan for smoke removal and dust collection systems
Smoke and Dust Treatment

Y5-48 Boiler Induced Draft Fan

For boiler exhaust routes where the fan must overcome resistance from smoke-removal and dust-collection equipment.

Models: No.4C / 5C / 6.3C / 8C / 10C / 12.5C.

View Y5-48 →
Y8-39 Y9-38 high resistance boiler induced draft fan
Higher Resistance Direction

Y8-39 / Y9-38 Boiler ID Fan

For boiler, kiln and furnace exhaust routes with higher resistance, longer ducting or more demanding hot-gas conditions.

Reference: 0.5–35 t boiler applications · up to 250°C standard direction.

View Y8-39 / Y9-38 →
Larger and Combined Boiler Draft Series

Additional ID Fan Directions for Wider Boiler Duties

These series extend the selection range for medium and large boiler systems. Confirm the induced-draft configuration before quotation.

Y4-73 boiler induced draft configuration for large steam boiler systems

G/Y4-73 Boiler Centrifugal Fan

Choose the Y4-73 direction for flue gas exhaust. G4-73 is the clean-air-side configuration.

Boiler range: 2–670 t/h, subject to the actual operating point.

View G/Y4-73 →
GY5-51 boiler forced and induced draft fan series

GY5-51 Boiler Draft Fan

A combined forced-draft and induced-draft direction for steam boilers and higher-pressure fluidized-bed boiler duties.

Reference: 2–670 t/h · operating temperature direction up to 250°C.

View GY5-51 →
Y6-41 induced draft configuration for small and medium industrial boilers

GY6-41 Industrial Boiler Fan

For 0.5–10 t/h industrial boiler rooms. Select the Y6-41 direction for induced draft and flue gas exhaust.

Suitable for small and medium boiler-room air-supply and exhaust matching.

View GY6-41 →
GY6-51 large capacity boiler induced draft fan

GY6-51 Large-Capacity Draft Fan

For large steam boiler and fluidized-bed boiler draft systems requiring a wide airflow and pressure envelope.

Reference: 11,000–667,000 m³/h · 1,859–10,980 Pa.

View GY6-51 →
Preliminary Comparison

Which Boiler ID Fan Series Should Be Reviewed First?

The table is a product-navigation tool, not a substitute for a fan curve or final technical selection.

Product Series Preliminary Position Typical Review Focus Important Confirmation
Y6-30 Compact boiler ID fan Small and medium boiler exhaust C/D drive, airflow, pressure and layout
Y5-47 Standard industrial boiler duty Regular flue gas extraction after dust removal Temperature, ash and collector resistance
Y5-48 Smoke and dust treatment route Dust collector and long exhaust route Loaded resistance and duct losses
Y8-39 / Y9-38 Higher-resistance exhaust Boiler, furnace or kiln hot-gas route Temperature-oriented structure and material
Y4-73 / GY Series Wider boiler scale and duty envelope Medium to large boiler and fluidized-bed systems Confirm induced-draft configuration, drive and motor
Selection note: Boiler capacity and model family are only preliminary filters. Final selection must be checked against the fan curve at the required airflow and total pressure, corrected for actual gas density and temperature where applicable.
New Boiler Projects

Select from the Complete Exhaust Route

For a new system, the fan duty should include the resistance of the boiler body, heat-recovery section, dust collector, scrubber, dampers, elbows, ducting and chimney route.

● Boiler capacity and fuel
● Design flue gas volume
● Required static or total pressure
● Normal and maximum temperature
● Dust collector and gas-treatment equipment
● Duct layout, chimney and site altitude

Replacement Fan Projects

Match the Existing Interface and Correct the Real Problem

For an existing boiler ID fan replacement, operating data and connection dimensions are as important as the original model number.

● Fan and motor nameplate photos
● Existing airflow, pressure, speed and power
● Inlet, outlet and foundation dimensions
● Rotation and discharge angle
● Current problem: low draft, overload, wear or vibration
● Site photos, drawings and available installation space

Configuration Review

Configuration Must Follow the Flue Gas Condition

Drive Arrangement

C-type, D-type or another supported transmission arrangement should be reviewed according to model size, speed, temperature, motor layout and maintenance access.

Material and Wear

Dust concentration, ash hardness, moisture and corrosive components affect impeller material, casing treatment, wear protection and service-life expectations.

Temperature Structure

Continuous and peak temperature should be stated separately. Bearing isolation, shaft arrangement, cooling and motor position depend on the verified temperature duty.

Rotation and Outlet Angle

Left-hand or right-hand rotation and the discharge angle must match the actual duct direction. Confirm the viewing side before production.

Motor and Control

Provide voltage, frequency, phase, enclosure, insulation and control method. Damper control and variable-speed control should be reviewed against the operating range.

Connection and Foundation

For replacement projects, send inlet, outlet, base and shaft-center dimensions. A drawing or measured sketch helps reduce interface risk.

Technical FAQ

Boiler Induced Draft Fan Questions

What is the main function of a boiler induced draft fan?

It pulls flue gas through the boiler exhaust route and helps maintain the required furnace negative pressure while overcoming the resistance of connected equipment and ducting.

Can the model be selected only from boiler capacity?

No. Boiler capacity provides an initial direction, but the final model must use the required airflow, total pressure, gas temperature, density, dust condition, treatment equipment and installation arrangement.

What resistance should be included in ID fan pressure?

Include the pressure losses of the boiler body, heat-recovery section, dust collector, scrubber, dampers, elbows, transitions, duct friction, chimney and discharge route.

How should a replacement boiler ID fan be specified?

Send nameplate photos, current operating data, connection dimensions, foundation dimensions, rotation, outlet direction, motor standard, site photos and the problem that needs to be corrected.

What is the difference between this product page and the boiler ID fan system page?

This page compares QIYUE FAN product families and direct model entries. The boiler induced draft system page explains fan position, system resistance, new-project data and replacement-project selection logic in greater detail.

Continue the Selection Path

Related Boiler Fan Pages

Move from the induced-draft product family to the corresponding system guide, forced-draft family, high-temperature family or complete boiler fan selection guide.

Application

Boiler Induced Draft System

Review flue-gas route, dust-collector resistance, chimney discharge and negative-pressure requirements.

View ID System →
Product Family

Boiler Forced Draft Fans

Compare combustion-air supply, burner pressure and air-side fan directions before the furnace.

View FD Fans →
Product Family

High-Temperature Industrial Fans

Review furnace, kiln, boiler and thermal-process hot-gas fan directions.

View High-Temp Fans →
Selection Guide

Boiler Fan Selection Guide

Compare ID, FD and high-temperature fan duties from the complete boiler route.

Read Selection Guide →
Fan Selection and Quotation

Send Your Boiler ID Fan Operating Point

Provide boiler capacity, fuel, airflow, total pressure, normal and maximum flue gas temperature, dust condition, treatment equipment, duct layout, power supply, quantity and destination. For replacement projects, attach the existing fan nameplate and interface drawing.

Contact QIYUE FAN Send Photos by WhatsApp
sales@qiyuefan.com · +86 156 5330 5981

Hot Tags: boiler induced draft fans, China boiler induced draft fans manufacturers, suppliers, factory

Send Inquiry