Y6-30 Boiler Induced Draft Fan

Y6-30 Boiler Induced Draft Fan

The Y6-30 boiler induced draft fan is designed for extracting boiler flue gas and maintaining stable negative pressure in industrial boiler systems. It can be supplied with C-type or D-type drive, left-hand or right-hand rotation, and multiple outlet-angle arrangements. The fan is mainly composed of the impeller, casing, air inlet, air-regulating damper and transmission assembly. Available fan sizes, motor power, speed, airflow and total pressure should be selected according to the actual boiler capacity and system resistance. Qiyue Fan can configure the motor voltage, drive arrangement, rotation direction, outlet angle, surface treatment and material according to the operating temperature, gas composition, dust concentration and installation requirements. Stainless-steel or corrosion-resistant configurations are available subject to project confirmation.
Send Inquiry
Description
Boiler Induced Draft · Flue Gas Extraction · Application Selection
Y6-30 Boiler Induced Draft Fan
 

Y6-30 is used as a boiler induced draft fan for extracting flue gas and supporting stable negative pressure on the exhaust side of industrial boiler systems.

This page focuses on Y6-30 application and selection logic: where the fan works in the boiler exhaust route, what project data must be checked, and how induced-draft duty differs from forced-draft duty.

Detailed performance and dimensional data should be taken from verified technical documentation and the actual operating point rather than inferred from the generic Y6-30 name.

Y6-30 boiler induced draft fan for industrial boiler flue gas extraction
Y6-30 boiler induced draft fan for flue-gas extraction and negative-pressure support
Primary Duty
Induced Draft
boiler exhaust side
Medium
Flue Gas
after boiler / dust removal
Selection Basis
Duty Point
airflow + pressure
Verified Technical Data
Y6-30-12
manual-backed technical page
Project Check
Temperature + Dust
before final selection
 
Boiler Draft Role

Where Y6-30 Works in the Boiler Exhaust Route

 

The Y6-30 works on the exhaust side of the boiler system. Its job is to draw flue gas through the boiler body, ductwork and dust-removal equipment, then support stable discharge toward the chimney.

The fan must overcome the combined resistance of the boiler body, flue duct, dust collector, dampers and chimney route. This is why motor power or boiler tonnage alone is not enough for final selection.

View Boiler Induced Draft System →
01

Boiler Furnace

Combustion gas is generated.

02

Flue Duct

Ductwork adds resistance.

03

Dust Collector

Dust-removal equipment adds pressure loss.

04

Y6-30 ID Fan

Provides induced draft and negative pressure.

05

Chimney

Flue gas is discharged.

 
Verified Technical Reference

Verified Y6-30-12 Technical Data Is Published Separately

The original manual available to us is titled Y6-30-12 and provides verified performance, motor, dimensional and installation data for No.3.5C through No.8.6C. Those technical values are kept on the Y6-30-12 page rather than being generalized to every product that may be referred to simply as Y6-30.

Manual-Backed Technical Page
Y6-30-12 Boiler Induced Draft Fan

The Y6-30-12 page carries the original-manual performance range, motor references and engineering dimensions. Use it when you need verified technical data rather than generic Y6-30 selection guidance.

 
Selection Checkpoints

Before Selecting a Y6-30 Boiler ID Fan

01

Boiler Duty

Boiler capacity, fuel type, operating load and required induced draft.

02

Airflow and Pressure

Required airflow and total/static pressure at the same duty point.

03

Flue Gas Condition

Temperature, dust, moisture, ash abrasiveness and corrosive components.

04

Dust Collector Resistance

Cyclone, bag filter, wet collector or other equipment pressure loss.

05

Site Layout

Rotation, outlet direction, foundation and maintenance space.

06

Motor Supply

Voltage, frequency and project-specific motor requirements.

If pressure is not known, use the Static Pressure Unknown Guide.

 
ID Fan vs FD Fan

Y6-30 Is for Induced Draft, Not Forced Draft

A boiler induced draft fan extracts flue gas after combustion, while a forced draft fan supplies combustion air before the furnace. The two duties are not interchangeable.

Fan Type Position Function Selection Focus
Y6-30 Boiler ID Fan After boiler / dust removal Extract flue gas and support negative pressure Temperature, dust, system resistance, chimney route
Boiler Forced Draft Fan Before furnace Supply combustion air Combustion airflow and duct resistance
 
Project Configuration

Drive, Rotation and Outlet Arrangement Must Match the Project

Drive Arrangement

Confirm the drive arrangement from verified technical documentation, required speed, motor arrangement and maintenance conditions.

Rotation Direction

Left-hand or right-hand rotation must match the actual site duct arrangement.

Outlet Direction

Discharge orientation should be confirmed from the project layout rather than assumed.

Motor Configuration

Voltage, frequency, enclosure and destination-market requirements can be reviewed.

 
Working Conditions

When Y6-30 Fits and When Another Boiler Fan Should Be Reviewed

TYPICAL DIRECTION

Boiler Flue-Gas Extraction

Boiler induced draft, exhaust after boiler body, negative-pressure support, dust-removal-system exhaust and replacement of an existing ID fan.

SPECIAL REVIEW

Conditions Outside Standard Review

Very high temperature, abrasive ash, heavy dust, corrosive gas, acid-dew-point risk, substantially larger duty or forced-draft service should trigger review of another boiler fan type.

 
Buyer FAQ

Y6-30 Boiler Induced Draft Fan FAQ

What is Y6-30 used for?

It is used on the boiler exhaust side to extract flue gas and support stable negative pressure.

Is Y6-30 an ID fan or FD fan?

Y6-30 is used for induced draft. Forced draft service should be selected separately.

Why is there no generic Y6-30 performance table here?

The original manual available to us is titled Y6-30-12 and covers No.3.5C through No.8.6C. We therefore keep those verified values on the Y6-30-12 technical page rather than presenting them as universal data for the generic Y6-30 name.

What data is needed for selection?

Send boiler capacity, fuel type, airflow, pressure, flue-gas temperature, dust condition, dust-collector resistance, duct layout, motor supply, rotation and outlet requirement.

When should another boiler fan be reviewed?

Review another boiler fan type for substantially higher duty, very high temperature, abrasive ash, corrosive gas, acid-dew-point risk or forced-draft service.

Boiler ID Fan Selection

Send Your Boiler Exhaust Parameters

Send airflow, pressure, flue-gas temperature, dust concentration, dust-collector resistance, duct layout, rotation, outlet direction, voltage, frequency and quantity.