9-12 High Pressure Centrifugal Fan

9-12 High Pressure Centrifugal Fan

9-12 High Pressure Centrifugal Fan is designed for cupola furnace blowing, melting furnace air supply, forging furnace ventilation and high pressure industrial air supply. It is suitable for conveying non-corrosive, non-flammable and non-viscous gas, with medium temperature not exceeding 80℃. The fan covers airflow from 1700 to 9039 m³/h and total pressure from 11590 to 21719 Pa according to different models. Qiyue Fan provides model selection support according to airflow, pressure, motor power, outlet direction and working conditions.
Send Inquiry
Description
High Resistance Air Supply Fan

9-12 High Pressure
Centrifugal Fan

 

The 9-12 high pressure centrifugal fan is used when an air system must overcome long duct runs, equipment pressure loss, furnace auxiliary resistance or process air delivery requirements.

This series is selected by working point: airflow, total pressure, resistance source, medium condition, motor power, outlet direction, rotation and installation space.

9-12 High Pressure Centrifugal Fan
Airflow
1700-9039 m³/h
Pressure
11590-21719 Pa
Airflow Range
1700-9039
m³/h for high-resistance air systems.
Pressure Range
11590-21719
Pa total pressure reference range.
Power Range
15-90kW
Motor selection depends on duty point.
Fan Sizes
6.8-9D
6.8 / 7.1 / 7.4D / 7.7D / 8D / 9D.
Product Positioning

Pressure Support for Long Ducts and Process Equipment

The 9-12 series is selected when the challenge is maintaining airflow after the air passes through long ducts, elbows, equipment chambers, dampers or high-resistance process points. It is not a general low-pressure ventilation fan.

This fan is often used for high pressure air supply, process ventilation, furnace auxiliary air delivery and non-corrosive gas conveying. The correct model depends on total pressure and airflow together, not only on the model number.

When the working point is close to the upper pressure range, motor power, fan speed, duct route, safety margin and continuous operation requirement should be checked before confirming the final fan.

Resistance Route

Typical Resistance Points in a 9-12 Air System

The 9-12 fan should be selected after the main pressure-loss points are understood. A long duct system may require more pressure than a short open exhaust layout even when airflow is similar.

01
Air Inlet

Check inlet loss and inlet condition.

02
Long Duct

Duct length and elbows add resistance.

03
Equipment Chamber

Equipment pressure loss should be included.

04
Process Point

Final pressure must still support airflow.

Working Condition

Where the 9-12 Fan Is Commonly Reviewed

Suitable Direction
Long duct air supply
Process equipment air delivery
Industrial forced blowing
Furnace auxiliary air delivery
Non-corrosive gas conveying
Confirm Before Selection
Required airflow in m³/h or CFM
Total pressure or static pressure
Resistance source and duct route
Medium temperature and dust content
Outlet direction, rotation and motor standard
Performance Data

9-12 Main Fan Sizes and Motor Options

The following performance table is for preliminary selection. Final selection should be confirmed against the actual working point, system resistance and medium condition.

Fan No. Speed r/min Total Pressure Pa Airflow m³/h Motor Model Power kW
9-12 6.8 2930 11590-11740 1700-4460 Y160M2-2 / Y180M-2 15-22
9-12 7.1 2900 12347-12739 2074-4990 Y160M2-2 / Y200L1-2 15-30
9-12 7.4D 2900 13416-13465 2349-6315 Y160M2-2 / Y225M-2 15-45
9-12 7.7D 2930 14543-14583 2349-6315 Y180M-2 / Y225M-2 22-45
9-12 8D 2950 16216-16729 2996-7133 Y200L1-2 / Y250M-2 30-55
9-12 9D 2970 20803-21719 4295-9039 Y225M-2 / Y280M-2 45-90

Note: If the required pressure is close to the upper range, motor power, fan speed and safety margin should be reviewed together.

Application Scenarios

Typical 9-12 High Pressure Fan Applications

Long Duct Air Supply

Used where duct length, elbows and branch lines create clear pressure loss.

Process Equipment Air Delivery

Suitable for equipment requiring stable airflow under higher system resistance.

Industrial Forced Blowing

Applied in forced-air systems where pressure stability is more important than simple exhaust volume.

Furnace Auxiliary Air

Used as auxiliary air delivery where furnace or process resistance must be overcome.

Non-Corrosive Gas Conveying

For clean or low-dust gas conveying where the medium is non-corrosive and non-viscous.

Replacement Projects

Model comparison based on old fan data, pressure loss and installation direction.

FAQ

FAQ About 9-12 High Pressure Centrifugal Fan

What is the 9-12 high pressure centrifugal fan used for?

It is used for high pressure air supply, long duct ventilation, process equipment air delivery, furnace auxiliary air and non-corrosive gas conveying.

What airflow and pressure range does the 9-12 fan cover?

The reference airflow range is 1700-9039 m³/h, and the total pressure range is 11590-21719 Pa.

How should I confirm the working point?

Confirm airflow, total pressure or static pressure, duct resistance, medium temperature, dust content, humidity, outlet direction, rotation direction and motor voltage.

Can 9-12 be used for corrosive or sticky gas?

Standard selection is for non-corrosive and non-viscous gas. Corrosive, sticky or high-temperature gas should be reviewed before material and configuration selection.

Send Your 9-12 Fan Working Point

Share airflow, pressure, duct resistance, medium temperature, application, outlet direction, rotation, motor voltage and quantity. QIYUE FAN will review whether the 9-12 high pressure centrifugal fan fits your project.