4-72 Centrifugal Ventilation Fan

4-72 Centrifugal Ventilation Fan

4-72 centrifugal ventilation fan for factory ventilation, workshop exhaust, air supply and general industrial airflow systems. Suitable for clean air or non-corrosive gas conveying under ordinary working conditions. Model selection can be based on airflow, total pressure, speed, motor power, outlet angle and installation direction.
Send Inquiry
Description
Industrial Centrifugal Ventilation Fan

4-72 Centrifugal Ventilation Fan

 

General-purpose centrifugal fan for factory ventilation, workshop exhaust, equipment-room air supply and ordinary industrial air-handling systems.

Suitable for clean air or non-corrosive gas under normal-temperature ventilation conditions. Model selection is based on airflow, total pressure, speed, drive arrangement, outlet direction and installation space.

4-72 centrifugal ventilation fan for factory ventilation

Compact A-type configuration shown. B-type, C-type and D-type arrangements are available on selected sizes for different capacities and installation layouts.

2.8A–20B
Reference Model Range
A / B / C / D
Drive Arrangements
250–2900
Reference Speed, r/min
1.1–220 kW
Reference Motor Power
≤80°C
Standard Medium Temperature
≤150 mg/m³
Dust / Hard Particles
Quick Overview

General-Purpose Centrifugal Fan for Ordinary Industrial Ventilation

 

The 4-72 centrifugal ventilation fan is designed for air supply, exhaust ventilation, workshop air exchange, equipment-room heat removal and general factory ventilation. It is primarily selected for conveying ordinary air or non-corrosive gas where moderate pressure and stable airflow are required.

The final model should not be chosen by fan number alone. Required airflow, total pressure, operating temperature, medium condition, drive type, rotation direction, outlet angle and available installation space should be confirmed before quotation.

Operating Boundary

Where the 4-72 Fan Fits - and Where It Does Not

 
Suitable Applications
Clean-air supply and exhaust
Workshop and factory ventilation
Equipment-room heat discharge
Warehouse air circulation
Ordinary non-corrosive gas delivery
Requires Special Review
Heavy dust or abrasive particles
Corrosive chemical gas
High-temperature flue gas
Flammable or explosive gas
High-resistance systems beyond the fan range
Standard catalog boundary: the conveyed gas should contain no sticky substances; dust and hard-particle concentration should not exceed 150 mg/m³; gas temperature should not exceed 80°C. For corrosive, abrasive, high-temperature or explosion-proof service, the working medium and required construction must be reviewed separately.
Drive Arrangement

A-Type, B-Type, C-Type and D-Type Configurations

 

The 4-72 series uses different drive arrangements according to fan size, speed and installation requirements. Final configuration should be confirmed together with the duty point and project layout.

A
DIRECT DRIVE

A-Type Direct Drive

Compact arrangement used on smaller sizes. The impeller is mounted on the motor shaft for a short transmission path and reduced installation footprint.

B
BELT DRIVE

B-Type Belt Drive

Used on selected large-size configurations. Motor, pulley and foundation arrangement are matched to the selected model and site layout.

C
BELT DRIVE

C-Type Belt Drive

Separate fan shaft and motor arrangement provides flexibility for speed matching, maintenance access and installation positioning.

D
SEPARATE SHAFT

D-Type Drive

Separate shaft and bearing arrangement for selected sizes. Final pulley or coupling configuration is confirmed after duty-point selection.

Reference Performance

4-72 Performance Data and Model Coverage

 

The series covers multiple sizes and drive arrangements. Use the overview below for preliminary screening, then open the detailed technical groups as required.

Drive Type Catalog Sizes Typical Arrangement Selection Note
A-Type No.2.8A–6A Compact direct drive Compact direct-drive range; confirm duty point, speed and motor before order.
C-Type No.6C / 8C / 10C / 12C Belt drive Use where a separate fan shaft and belt-drive arrangement suits the project layout.
D-Type No.6D / 8D / 10D / 12D Separate shaft / drive arrangement Separate shaft / drive configuration; final bearing and transmission arrangement follows model selection.
B-Type No.16B / 20B Large-size belt-drive configuration Large-size belt-drive configuration; confirm motor, pulley, foundation and GA drawing for the selected model.

A-Type Detailed Performance Data - No.2.8A to No.6A

Reference rows for preliminary model screening. Final selection should be checked against the required airflow, total pressure and actual system resistance.

Model Speed
r/min
Total Pressure
Pa
Airflow
m³/h
Motor Power
kW
Motor Model
2.8A 2900 606–994 1131–2356 1.5 Y90S-2
3.2A 2900 792–1300 1688–3517 2.2 Y90L-2
3.2A 1450 198–324 844–1758 1.1 Y90S-4
3.6A 2900 989–1758 2664–5268 3 Y100L-2
3.6A 1450 247–393 1332–2634 1.1 Y90S-4
4A 2900 1320–2014 4012–7419 5.5 Y132S1-2
4A 1450 329–501 2006–3709 1.1 Y90S-4
5A 2900 2019–3187 7728–15455 15 Y160M2-2
5A 1450 502–790 3864–7728 2.2 Y100L1-4
6A 1450 724–1139 6677–13353 4 Y112M-4
6A 960 317–498 4420–8841 1.5 Y100L-6
The full 4-72 catalog contains additional speed points. Final model, motor and drive arrangement should be confirmed against the project duty point.

C-Type Catalog Coverage - No.6C / 8C / 10C / 12C

Arrangement: belt drive with separate fan shaft and motor. Detailed point-by-point catalog data should be checked after the target airflow and pressure are confirmed.

D-Type Catalog Coverage - No.6D / 8D / 10D / 12D

Arrangement: separate shaft / drive configuration. Final shaft, bearing and drive arrangement depend on the selected fan size and operating point.

B-Type Large-Size Coverage - No.16B / 20B

Arrangement: large-size belt-drive configuration. Motor, pulley, foundation and overall dimensions must be confirmed using the corresponding selected-model drawing.
Engineering Drawing

Reference Outline & Installation Dimensions

 

The drawing below is the catalog reference for 4-72-12 / B4-72-12 No.2.8A–6A. Final overall dimensions depend on fan size, motor, drive arrangement and discharge orientation.

4-72 centrifugal ventilation fan outline and installation dimensions
Compact reference preview - click to open the full-size drawing.

Drawing Scope and Dimension Notes

Drawing scope: 4-72-12 / B4-72-12 No.2.8A–6A reference configuration. For other sizes and drive arrangements, request the corresponding GA drawing with the required duty point. Project-specific dimensions are supplied after model selection.

What Changes the Final Overall Dimensions?

Fan size, drive arrangement, motor frame, outlet angle, rotation direction, base frame and project-specific installation requirements can all change the final GA dimensions.
Selection Information

Information Needed for Correct Model Selection

 
01

Airflow & Pressure

Provide the design airflow in m³/h plus total pressure, static pressure or calculated duct-system resistance.

02

Medium, Temperature & Altitude

Confirm clean air, dusty air, hot air or process gas, together with operating temperature and site altitude.

03

Direction & Electrical

Confirm rotation, discharge angle, inlet orientation, installation space, voltage, frequency and motor protection requirements.

Applications

Typical Industrial Ventilation Applications

 
Primary Application

Factory & Workshop Air Exchange

General ventilation for industrial buildings, workshops and production areas, including ordinary exhaust for warm air, odor and suitable process air.

Supply & Circulation

Air Supply & Warehouse Circulation

Fresh-air supply, auxiliary air delivery and circulation support for storage areas and large enclosed spaces.

Equipment Support

Equipment Rooms & Process Air Handling

Heat-removal support for machinery rooms, utility areas and general production equipment or duct systems.

Project Configuration

Available Configuration Options

 
Item Available Option Selection Purpose
Drive Type A-type, B-type, C-type or D-type Match capacity, maintenance preference and installation layout
Motor Voltage, frequency, protection level and brand options Match local power supply and project specification
Rotation / Outlet Clockwise or counter-clockwise rotation and customized discharge angle Fit duct routing and available installation space
Base Frame Standard or project-specific steel base Support installation accuracy and site assembly
Accessories Inlet damper, flexible connector, vibration isolator and guard Improve system integration and operational safety
FAQ

4-72 Centrifugal Ventilation Fan FAQ

 

What is the 4-72 centrifugal fan mainly used for?

It is mainly used for factory ventilation, workshop exhaust, air supply, equipment-room ventilation and ordinary industrial air-handling systems.

Can the 4-72 fan handle dusty air?

For the standard catalog condition, the gas should contain no sticky substances and dust/hard particles should not exceed 150 mg/m³. Abrasive or heavier dust service should be reviewed separately before selection.

How do I choose between A-type, B-type, C-type and D-type?

The choice depends on fan size, speed, motor arrangement, maintenance preference and installation space. Final configuration should be confirmed together with the duty point and project layout.

What information is required for quotation?

Please provide airflow, total pressure, medium, temperature, altitude, voltage, frequency, rotation direction, discharge angle, quantity and any project-specific motor or accessory requirement.

Send Your 4-72 Fan Duty Point

Send airflow, total pressure, medium, temperature, drive preference, installation direction and quantity. QIYUE FAN will review the suitable model, motor and outlet arrangement.

Hot Tags: 4-72 centrifugal ventilation fan, China 4-72 centrifugal ventilation fan manufacturers, suppliers, factory

Send Inquiry