4-79 Centrifugal Ventilation Fan

4-79 Centrifugal Ventilation Fan

4-79 Centrifugal Ventilation Fan is designed for indoor air supply and exhaust ventilation in general factories, workshops and large buildings. It is suitable for conveying clean air or non-flammable, harmless and non-corrosive gas. The conveyed gas should not contain viscous substances, dust and hard particles should not exceed 150 mg/m³, and gas temperature should not exceed 80°C.
Send Inquiry
Description
Air Supply and Exhaust Ventilation

4-79 Centrifugal
Ventilation Fan

 

The 4-79 centrifugal ventilation fan is used in factory buildings, workshops, warehouses, machinery rooms and large indoor spaces where air supply, exhaust air discharge or general air exchange is required.

This series is suitable for clean air and ordinary non-corrosive gas conditions. Before selection, please confirm airflow, total pressure, medium temperature, dust content, duct layout, outlet direction and motor requirements.

4-79 centrifugal ventilation fan for factory air supply and exhaust ventilation
Working Medium
Clean Air
Temperature
Not Above 80°C
 
990-20850
Air Volume m³/h
 
176-3334
Total Pressure Pa
 
≤150 mg/m³
Dust Limit
 
≤80°C
Gas Temperature
Product Role

Ventilation Fan for Indoor Air Exchange Systems

The 4-79 series is mainly selected for ordinary indoor ventilation tasks. In a project, it can work as an air supply fan to introduce fresh air, or as an exhaust fan to remove used air from workshops, buildings and enclosed equipment areas.

Unlike special-purpose fans for flue gas, dust collection, corrosion or explosion-proof sites, the 4-79 fan is intended for relatively clean and non-aggressive airflow. This makes the medium condition an important checkpoint before quotation.

For replacement projects, old nameplate data, existing duct size, motor power and outlet direction can help QIYUE FAN compare the current working point and review whether a 4-79 model is suitable.

Operating Medium Limits

Check the Air Condition Before Model Selection

Clean or Ordinary Air

Suitable for common air exchange, air supply and exhaust ventilation without corrosive or flammable gas risk.

No Viscous Substance

The conveyed gas should not contain sticky material that may adhere to the impeller or casing.

Dust Content Control

Dust and hard particles should normally be within 150 mg/m³ for ordinary ventilation selection.

Temperature Control

The gas temperature should not exceed 80°C. Hot gas projects should be reviewed separately.

Airflow Direction and Use

Air Supply or Exhaust: Confirm the System Layout

Supply Side

Fresh Air Delivery

Used to deliver air into workshops, buildings, equipment rooms or process areas when the duct layout requires positive air supply.

Exhaust Side

Used Air Discharge

Used to discharge ordinary indoor air, heat accumulation or general exhaust air from enclosed spaces under non-corrosive conditions.

Circulation Support

Air Exchange Balance

Used as part of a ventilation system where air inlet, exhaust outlet and duct resistance must be balanced together.

Technical Overview

Key Data for 4-79 Fan Selection

Fan Series
4-79 centrifugal ventilation fan
Main Function
Indoor air supply, exhaust ventilation and general air exchange
Typical Sites
Factory buildings, workshops, warehouses, machinery rooms and large indoor spaces
Working Medium
Non-flammable, harmless and non-corrosive gas without viscous substances
Selection Inputs
Air volume, total pressure, duct route, medium condition, temperature, motor power, rotation direction and outlet angle
Performance Reference

4-79 Fan Performance Range

The following data is for preliminary comparison. The final model should be confirmed after checking the actual system resistance and required ventilation volume.

Range Summary

Use this range to judge whether the 4-79 fan series is close to your project demand.

Item Reference Range Why It Matters
Air Volume 990-20850 m³/h Determines ventilation capacity for supply or exhaust air.
Total Pressure 176-3334 Pa Must cover duct resistance and outlet losses.
Speed 960-2900 r/min Affects pressure, airflow, motor power and noise level.
Motor Power 0.75-15 kW Confirmed after matching model and working point.

Representative Models

Typical reference values for early communication and model comparison.

Model Speed Air Volume Total Pressure Motor Power
3A 2900 r/min 1970-3830 m³/h 1196-725 Pa 1.5 kW
3A 1450 r/min 990-1910 m³/h 304-176 Pa 0.75 kW
3.5A 2900 r/min 3120-6070 m³/h 1627-980 Pa 3 kW
4A 2900 r/min 4670-9080 m³/h 2316-1274 Pa 5.5 kW
4.5A 2900 r/min 6640-12920 m³/h 2696-1618 Pa 11 kW
5A 2900 r/min 9100-17720 m³/h 3334-2000 Pa 15 kW
6A 1450 r/min 4890-15320 m³/h 1196-706 Pa 5.5 kW
7C 1250 r/min 10820-20850 m³/h 1206-715 Pa 7.5 kW

Note: Performance data is for preliminary selection. Please send detailed airflow, pressure and working conditions before quotation.

Project Checklist

Information Needed for 4-79 Fan Selection

To avoid selecting a fan only by model name, please prepare the following information before quotation. These points help confirm the working point, motor configuration and installation arrangement.

1. Airflow Demand

Required m³/h or existing fan air volume.

2. Pressure Requirement

Total pressure, static pressure or duct resistance.

3. Air Condition

Temperature, dust content, humidity and gas composition.

4. Installation Direction

Outlet angle, rotation direction, motor position and base layout.

Application Scenarios

Where 4-79 Fans Are Commonly Used

Factory Buildings

General air supply and exhaust for ordinary industrial buildings.

Production Workshops

Air exchange support where the gas is not corrosive or explosive.

Warehouses

Air circulation and exhaust assistance for enclosed storage areas.

Machinery Rooms

Ventilation support for heat discharge and indoor air replacement.

Large Building Spaces

Air delivery or exhaust for large indoor ventilation systems.

Replacement Projects

Replacement of old general ventilation fans after checking nameplate data and site layout.

FAQ

FAQ About 4-79 Centrifugal Ventilation Fan

Is the 4-79 fan used for air supply or exhaust?

It can be used for both air supply and exhaust ventilation, depending on the duct system and project layout.

What gas conditions are suitable for 4-79 centrifugal fans?

The gas should be non-flammable, harmless and non-corrosive, without viscous substances. Dust and hard particles should normally be within 150 mg/m³.

What if the gas temperature is higher than 80°C?

For gas temperature above 80°C, a boiler fan or high-temperature fan should be reviewed instead of selecting a standard 4-79 ventilation fan directly.

How can QIYUE FAN check a replacement model?

Please send the old fan nameplate, airflow, pressure, motor power, rotation direction, outlet angle, photos and installation dimensions for comparison.

Send Your 4-79 Fan Parameters

Share airflow, total pressure, air condition, temperature, duct layout, voltage, frequency, outlet direction and quantity. QIYUE FAN will review whether the 4-79 centrifugal ventilation fan fits your project.