Centrifugal Fan Arrangement Types Explained: Arrangement 1, 3, 4, 7, 8, 9 And 10

Jul 23, 2026 Leave a message

QIYUE FAN · FAN SELECTION GUIDE

Centrifugal Fan Arrangements 1, 3, 4, 7, 8, 9 & 10

Bearing Layout, Wheel Position, Drive Type, SWSI & DWDI Configurations

A centrifugal fan arrangement identifies how the impeller, shaft, bearings, motor and drive system are mechanically positioned. The arrangement affects installation space, bearing support, motor location, transmission method, maintenance access and foundation design.

Get Fan Selection Support View Centrifugal Fans
Drive Method
Direct · Belt · Coupling
Bearing Support
Overhung · Between Bearings
Motor Position
Base · Pedestal · Internal
Inlet Configuration
SWSI · DWDI

Centrifugal fan arrangement types including Arrangement 1 4 7 9 10 and DWDI

Engineering note: Arrangement numbers describe mechanical configuration, not fan performance or efficiency. Airflow and pressure alone are not enough to determine the correct arrangement.
Mechanical Configuration

What Does a Centrifugal Fan Arrangement Number Mean?

A centrifugal fan arrangement number describes the physical relationship between the impeller, fan shaft, bearings, motor and drive components. If you are new to centrifugal fan structure and airflow principles, start with What Is a Centrifugal Fan? before comparing arrangement numbers. It helps engineers understand whether the wheel is overhung or positioned between bearings, whether the motor is mounted separately or on the fan structure, and whether power is transmitted through belts, a coupling or directly through the motor shaft.

Two centrifugal fans can produce similar airflow and pressure while using very different arrangements. The final arrangement should therefore be confirmed together with fan size, speed, motor power, process temperature, shaft loading, foundation and maintenance requirements.

Wheel Position
Overhung or Center-Hung
Determines shaft and bearing support requirements.
Bearings
Position Matters
Arrangement 1 and Arrangement 3 use fundamentally different bearing layouts.
Transmission
Motor to Wheel
Direct, belt and coupling-connected layouts require different service space.
Installation
Space & Access
Motor removal, bearing inspection and belt replacement must remain accessible.
Two Different Naming Systems

Arrangement Numbers vs A–F Drive Types

Numbered fan arrangements describe the complete mechanical layout, especially the relationship between the wheel, shaft, bearings and motor. A–F codes commonly used with Chinese centrifugal fan series describe another drive and support naming system.

They are related concepts, but there is no universal one-to-one conversion between an A–F code and Arrangement 1, 3, 4, 7, 8, 9 or 10.

Inlet Configuration

SWSI and DWDI Centrifugal Fan Arrangements

SWSI

Single Width, Single Inlet

An SWSI centrifugal fan uses one inlet and a single-width impeller. Common numbered arrangements include Arrangement 1, 3, 4, 7, 8, 9 and 10, together with application-specific variants.

DWDI

Double Width, Double Inlet

A DWDI centrifugal fan uses a wider double-inlet impeller with airflow entering from both sides. The shaft, two inlet structures, bearing locations and motor arrangement must be coordinated with the larger double-width assembly.

Arrangement Visual Reference

Common Centrifugal Fan Arrangement Groups

These diagrams are useful for identifying common mechanical layouts. They are reference illustrations only; final bearing positions, motor location, dimensions, rotation and discharge direction should be confirmed on the approved general arrangement drawing.

SWSI · GROUP 01

Arrangements 1, 3, 3F, 3SI, 4 and 4S

SWSI centrifugal fan Arrangements 1 3 3F 3SI 4 and 4S

SWSI · COUPLING / DIRECT GROUP

Direct-Drive and Coupling-Connected Variants

SWSI direct drive and coupling connected centrifugal fan arrangements

BELT DRIVE · GROUP

Arrangements 9, 9F, 9H, 9ST, 9SS and 10

Centrifugal fan Arrangement 9 Arrangement 10 bearing and motor layouts

DWDI · GROUP

DWDI Arrangements 3, 3DI, 3F, 7 and 7DI

DWDI centrifugal fan Arrangement 3 and Arrangement 7 configurations

Core Numbered Arrangements

Arrangement 1, 3, 4, 7, 8, 9 and 10 Explained

The following sections focus on the mechanical distinctions most useful for fan selection, replacement projects and bearing-layout identification.

Arrangement 1

Arrangement 1 Fan – Overhung Wheel with Independent Bearings

In a typical Arrangement 1 SWSI fan, the impeller is overhung on a separate fan shaft. Two fan bearings support the shaft on a pedestal or bearing base. The motor is separate from the impeller shaft and the fan may use belt drive or another suitable shaft-drive configuration depending on the design.

The key identifying feature is the overhung wheel with a separately supported fan shaft. Bearing spacing, shaft diameter, pulley position and motor location must be checked on the drawing.

Arrangement 3

Arrangement 3 Fan Bearing Configuration – Wheel Between Bearings

The defining feature of an Arrangement 3 fan bearing configuration is that the impeller is mounted on a fan shaft between two bearings. The bearings may be supported by the fan casing or mounted on independent bearing pedestals, depending on the fan construction.

This between-bearing layout gives a different shaft-support condition from an Arrangement 1 overhung fan. Arrangement 3 can be used with belt or shaft-connected drive configurations according to the specific fan design.

Arrangement 4

Arrangement 4 Fan – Impeller Mounted on Motor Shaft

Arrangement 4 is a direct-drive centrifugal fan layout. The impeller is overhung directly on the motor shaft, so there is no separate fan shaft or external fan bearing set. The compact structure reduces transmission components, but motor speed, motor bearing load, operating temperature and access for motor removal must be reviewed carefully.

Arrangement 7

Arrangement 7 Fan – Between-Bearing Shaft with Coupling Drive

Arrangement 7 is generally based on an Arrangement 3-style between-bearing fan shaft, but the motor or prime mover is connected to the fan shaft through a coupling. Coupling alignment, bearing centerline, common-base rigidity and motor-removal clearance are therefore important parts of the installation design.

Arrangement 8

Arrangement 8 Fan Bearing Configuration – Overhung Wheel with Inline Motor

Arrangement 8 generally retains the overhung wheel and independent fan-bearing structure associated with Arrangement 1, while the motor is installed in line with the fan shaft on the fan base or support structure.

In an Arrangement 8 fan bearing layout, the fan shaft remains independently supported rather than placing the impeller directly on the motor shaft. Final coupling, bearing and pedestal geometry should be confirmed on the manufacturer's drawing.

Arrangement 9

Arrangement 9 Fan Bearing and Motor Layout

Arrangement 9 is a belt-driven configuration with an overhung impeller on a separately supported fan shaft. Two bearings are mounted on the bearing pedestal or fan base, while the motor is mounted outside the bearing pedestal structure.

Depending on the specific Arrangement 9 variant, the motor may be installed on the pedestal, an extended frame, the side of the pedestal or a swingout structure.

Arrangement 10

Arrangement 10 Fan Bearing and Belt-Drive Layout

Arrangement 10 is also a belt-driven overhung-wheel arrangement with an independent fan shaft and two fan bearings. The principal motor-position difference from Arrangement 9 is that the motor is installed inside the bearing pedestal or support structure.

The compact external footprint can be useful where installation space is limited, but motor cooling, inspection access, belt replacement and motor-removal clearance must be checked before finalizing the layout.

Bearing Layout Comparison

Arrangement 1 vs Arrangement 3 Fan Bearings

Arrangement 1
Overhung Impeller

The impeller is located outside the two-bearing span. The shaft is supported by two bearings on one side of the wheel.

Arrangement 3
Impeller Between Bearings

The impeller is positioned within the bearing span, with one bearing supporting the shaft on each side of the wheel.

Why this matters: The terms "Arrangement 1 fan bearing" and "Arrangement 3 fan bearing" are not simply different motor positions. They describe fundamentally different shaft-support relationships.
Arrangement Variants

Common SWSI and DWDI Arrangement Variants

Industrial fan manufacturers may use additional suffixes to identify motor frames, inlet boxes, swingout structures and double-inlet configurations. The exact designation should always be checked against the supplier drawing.

Arrangement 3F
Extended structural frame supports the fan and motor as an integrated assembly.
Arrangement 3SI
SWSI variant with integral inlet box and independent bearing support.
Arrangement 4S
Direct-drive swingout construction for improved wheel and casing access.
Arrangement 4VI / 4HI
Direct-drive inlet-mounted motor variants with vertical or horizontal motor orientation.
Arrangement 7SI
Coupling-connected SWSI construction with inlet-box and common-base features.
Arrangement 9F
Belt-drive version with an extended frame for motor support.
Arrangement 9H
Motor positioned horizontally beside the pedestal with an adjustable support.
Arrangement 9ST
Belt-driven swingout configuration with a top-mounted motor slide base.
Arrangement 9SS
Swingout construction with side-mounted motor and pivot-base support.
DWDI Arrangement 3
Double-width wheel positioned between bearing supports.
DWDI Arrangement 3DI
Double-inlet version with integral inlet boxes and independent bearing pedestals.
DWDI Arrangement 7 / 7DI
Coupling-connected double-width arrangements with independent or integrated support structures.
Quick Reference

Centrifugal Fan Arrangement Comparison

Arrangement Wheel / Bearing Layout Typical Drive Motor Relationship
1 Overhung wheel, separate fan shaft, two bearings Belt or shaft-connected Motor separate from wheel shaft
3 Wheel positioned between two bearings Belt or shaft-connected Independent fan shaft
4 No separate fan bearings Direct drive Wheel mounted directly on motor shaft
7 Wheel between bearings Coupling drive Motor coupled to fan shaft
8 Overhung wheel with independent fan bearings Inline direct / coupling connection Motor inline with fan shaft
9 Overhung wheel, two fan bearings Belt drive Motor outside bearing pedestal
10 Overhung wheel, two fan bearings Belt drive Motor inside bearing pedestal

Configuration descriptions are general engineering references. Manufacturer-specific variants and dimensional details must be confirmed on the final general arrangement drawing.

Selection Factors

How to Select the Correct Fan Arrangement

Arrangement should be selected after the aerodynamic duty is known, but airflow and pressure are only the starting point. Mechanical and installation conditions are equally important.

Installation Space
Overall footprint, duct direction, motor clearance and maintenance aisle.
Drive Method
Direct drive, belt speed adjustment or coupling-connected transmission.
Bearing Loads
Wheel position, fan speed, shaft length and transmitted load affect bearing design.
Process Temperature
High-temperature service may require the motor and bearings to remain away from hot gas.
Maintenance Access
Check bearing inspection, belt replacement, coupling alignment and motor removal.
Foundation
Common base, concrete foundation, vibration pads or spring isolation may affect layout.
RFQ Information

Information Required for Arrangement Selection

For a new fan or replacement project, send the technical data and installation information together. Existing fan drawings and nameplate photos are especially useful for replacement applications.

• Required airflow
• Static or total pressure
• Fan speed or motor speed
• Motor power, voltage and frequency
• Operating temperature
• Gas composition and dust concentration
• Preferred drive method
• Available installation space
• Inlet and outlet duct direction
• Foundation or vibration-isolation requirements
• Existing fan model or nameplate
• General arrangement drawing, if available
FAQ

Frequently Asked Questions About Fan Arrangements

What is an Arrangement 3 fan bearing configuration?

In an Arrangement 3 fan bearing configuration, the impeller is mounted on the fan shaft between two bearings. This is the main mechanical distinction from an Arrangement 1 fan, where the impeller is overhung outside the bearing span.

Where are the bearings located in Arrangement 8?

An Arrangement 8 fan generally uses an independently supported fan shaft with an overhung wheel. The motor is positioned inline with the fan shaft. Exact Arrangement 8 fan bearing positions and coupling geometry should be confirmed from the manufacturer's drawing.

What is the difference between Arrangement 1 and Arrangement 3?

Arrangement 1 uses an overhung wheel on a shaft supported by two bearings located on one side of the impeller. Arrangement 3 positions the wheel between two bearings.

What is the difference between Arrangement 4 and Arrangement 7?

Arrangement 4 mounts the impeller directly on the motor shaft and does not use separate fan bearings. Arrangement 7 uses a separately supported fan shaft with the motor connected through a coupling.

What is an Arrangement 9 fan bearing layout?

Arrangement 9 uses an overhung impeller, a separate fan shaft and two fan bearings on the bearing pedestal. It is normally belt driven, with the motor mounted outside the bearing pedestal structure.

What is an Arrangement 10 fan bearing configuration?

Arrangement 10 also uses an overhung wheel, separate fan shaft and two fan bearings. It is belt driven, with the motor installed inside the bearing pedestal or supporting structure.

What is the difference between Arrangement 9 and Arrangement 10?

Both are commonly belt-driven overhung-wheel configurations. Arrangement 9 places the motor outside the bearing pedestal, while Arrangement 10 places the motor inside the pedestal structure.

Are arrangement numbers the same as A, B, C, D, E and F drive types?

No. Both describe mechanical aspects of centrifugal fans, but they belong to different naming systems. Do not directly convert an A–F code into Arrangement 1, 3, 4, 7, 8, 9 or 10 without checking the actual fan drawing.

What is the difference between SWSI and DWDI?

SWSI means single width, single inlet. DWDI means double width, double inlet. DWDI fans admit air from both sides of the impeller and require a wider shaft and bearing arrangement.

Can a fan arrangement be selected from airflow and pressure only?

No. Airflow and pressure determine the aerodynamic operating duty. Arrangement selection must also consider fan speed, shaft and bearing loads, motor power, temperature, drive method, installation space, foundation and maintenance access.

Related Technical Resources

Continue Your Centrifugal Fan Selection

Start Here
What Is a Centrifugal Fan?
Review the basic airflow path, main components and centrifugal fan working principle before moving into mechanical arrangement details.
A–F Drive Arrangement Guide
Compare A, B, C, D, E and F drive and support terminology.
Rotation & Outlet Angle
Confirm CW / CCW rotation, viewing direction and discharge position.
Fan Performance Curve
Check airflow, pressure, shaft power and the actual operating point.
Motor Poles & Fan RPM
Review 50Hz / 60Hz speed, motor poles and operating RPM.
Centrifugal Fans
Browse QIYUE industrial centrifugal fan series after confirming duty.
Industrial Fan Selection Guide
Start from airflow, pressure, medium, temperature and installation.
QIYUE FAN Engineering Support

Need Help Confirming a Centrifugal Fan Arrangement?

Send the required airflow, pressure, fan speed, motor data, operating temperature, installation space, existing fan drawing or nameplate photo. QIYUE FAN can review the suitable bearing, shaft, drive and motor arrangement for your project.

Email Operating Conditions WhatsApp QIYUE FAN
QIYUE FAN | Industrial Fan Manufacturer | +86 15653305981 | sales@qiyuefan.com

Send Inquiry

Send Inquiry