FB Series Mine Explosion-Proof Electric Fan

FB Series Mine Explosion-Proof Electric Fan

FB Series Mine Explosion-Proof Electric Fan is designed for equipment cooling and local air circulation in underground mines and fixed ventilation points. With an explosion-proof motor, compact axial structure and durable steel housing, it provides reliable airflow for electrical rooms, machinery areas and other locations requiring safe ventilation in explosive atmospheres.
Send Inquiry
Description
Mine Explosion-Proof Electric Fan

FB Series Mine Explosion-Proof Electric Fan

 

Explosion-proof axial electric fan for equipment cooling, fixed-position ventilation and local air circulation in underground mines and industrial areas requiring explosion-proof airflow equipment.

This product is intended for near-field airflow around electrical rooms, pump stations, machinery areas and underground chambers. It is not a duct-connected press-in local ventilation fan.

FB series mine explosion-proof electric fan
Primary Duty
Equipment Cooling
Installation
Fixed Position
Power Range
0.55–30 kW
Voltage
380 / 660 V
0.55–30 kW
Rated Power Range
81–1930
Airflow, m³/min
380 / 660 V
Common Voltage
≤85 dB(A)
Noise Reference
Product Overview

Fixed-Position Airflow for Underground Equipment Cooling

The FB Series Mine Explosion-Proof Electric Fan is used for equipment cooling, fixed-position ventilation and local air circulation in underground mines and hazardous industrial environments requiring explosion-proof airflow equipment.

Typical locations include electrical rooms, machinery installations, pump stations, underground chambers and other fixed points where heat dissipation and continuous local airflow are required.

This product is different from duct-connected press-in local ventilation fans. For long-distance air delivery to roadways or tunneling faces, the correct selection should be an FB press-in fan or FBD counter-rotating local ventilation fan.

FB mine explosion-proof electric fan side view
Duty Boundary

Electric Fan vs Press-In Local Ventilation Fan

FB Explosion-Proof Electric Fan
Equipment cooling and local air circulation
Fixed ventilation points and short-range airflow
Electrical rooms, pump stations and machinery areas
Not primarily designed for long duct ventilation
FB / FBD Press-In Local Ventilation Fan
Connected to mine ventilation ducts
Air delivery to roadways and tunneling faces
Selected by airflow, pressure, duct diameter and distance
Used for long-distance or higher-resistance ventilation
Select the fan by ventilation duty rather than by the FB model name alone. For duct-connected local ventilation, review the FB press-in or FBD counter-rotating fan series.
Engineering Features

Built for Fixed Underground Ventilation Points

Explosion-Proof Design

For mine and hazardous-area airflow applications requiring confirmed explosion-proof equipment.

Compact Axial Structure

Short cylindrical housing provides direct airflow for near-field cooling and circulation.

Steel Housing

Welded steel casing and protective coating suit underground handling and industrial use.

Protective Front Guard

Protects the impeller area during fixed-position operation and routine handling.

Easy Installation

Mounting feet and lifting eyes support positioning, installation and maintenance.

Simple Maintenance

Accessible housing and stable assembly reduce routine maintenance complexity.

Product Views

Multi-Angle Product Display

FB mine explosion-proof electric fan angled view
Angled View
Overall structure
FB mine explosion-proof electric fan side view
Side View
Housing and nameplate
FB mine explosion-proof electric fan front guard view
Front Guard
Impeller protection
FB mine explosion-proof electric fan housing view
Housing View
Mounting structure
Technical Parameters

FB Series Model Range

The FB series covers 0.55–30 kW with airflow from 81 to 1930 m³/min. Final model selection should be confirmed according to airflow demand, voltage system, installation location and explosion-proof requirement.

High Power Models
Model Power Voltage Current Airflow Noise
FB-30000/(380/660) 30 kW 380/660 V 57.6/33.2 A 1930 m³/min ≤85 dB(A)
FB-22000/(380/660) 22 kW 380/660 V 44.7/25.7 A 1690 m³/min ≤85 dB(A)
FB-18500/(380/660) 18.5 kW 380/660 V 35.5/20.5 A 1570 m³/min ≤85 dB(A)
FB-15000/(380/660) 15 kW 380/660 V 31.6/18.2 A 1450 m³/min ≤85 dB(A)
Medium Power Models
Model Power Voltage Current Airflow Noise
FB-11000/(380/660) 11 kW 380/660 V 23.9/13.8 A 1270 m³/min ≤85 dB(A)
FB-7500/(380/660) 7.5 kW 380/660 V 15.5/8.9 A 700 m³/min ≤85 dB(A)
FB-5500/(380/660) 5.5 kW 380/660 V 11.6/6.7 A 630 m³/min ≤85 dB(A)
FB-4000/(380/660) 4 kW 380/660 V 8.6/4.9 A 570 m³/min ≤85 dB(A)
Low Power Models
Model Power Voltage Current Airflow Noise
FB-3000/(380/660) 3 kW 380/660 V 7.4/4.3 A 460 m³/min ≤85 dB(A)
FB-2200/(380/660) 2.2 kW 380/660 V 4.73/2.73 A 340 / 160 m³/min ≤85 dB(A)
FB-1500/(380/660) 1.5 kW 380/660 V 3.43/1.97 A 310 / 170 m³/min ≤85 dB(A)
FB-1100/(380/660) 1.1 kW 380/660 V 2.74/1.57 A 280 / 125 m³/min ≤85 dB(A)
FB-750/(380/660) 0.75 kW 380/660 V 1.91/1.10 A 240 / 110 m³/min ≤85 dB(A)
FB-550/(380/660) 0.55 kW 380/660 V 1.38/0.80 A 220 / 81 m³/min ≤85 dB(A)
Corresponding 660/1140 V versions are also available. Final voltage, current and explosion-proof requirements should be confirmed against the project power system and site conditions.
Applications

Typical Fixed Ventilation Applications

Equipment Cooling

Near motors, control systems and auxiliary machinery.

Electrical Rooms

Local air circulation for underground electrical areas.

Pump Stations

Airflow around pumps, motors and machinery installations.

Fixed Ventilation Points

Continuous local airflow at fixed underground positions.

Selection Information

Information Needed for Model Selection

Application Purpose

Cooling, room ventilation or local air circulation.

Required Airflow

Provide m³/min or room and heat-source data.

Voltage System

380/660 V, 660/1140 V or project voltage.

Installation Location

Mine chamber, electrical room or pump station.

Operating Environment

Dust, gas, humidity, temperature and safety needs.

Installation Method

Ground, fixed bracket or customized arrangement.

FAQ

FB Mine Explosion-Proof Electric Fan FAQ

Is this fan used for long-distance duct ventilation?

No. It is mainly used for equipment cooling, fixed-position ventilation and local air circulation. Use an FB press-in or FBD counter-rotating fan for long duct ventilation.

Can it be used in underground mines?

Yes. It is designed for underground mine applications and other locations requiring explosion-proof ventilation equipment.

What is the difference from an FB press-in fan?

This electric fan provides local airflow around equipment and fixed sites. An FB press-in fan connects to ventilation ducts and delivers air over a longer distance.

What information is needed for selection?

Please provide airflow demand, voltage, installation location, ventilation purpose, operating environment and explosion-proof requirement.

Request a Suitable FB Electric Fan Model

Send ventilation purpose, installation site, required airflow, voltage and explosion-proof requirements. QIYUE FAN will review a suitable model.

Hot Tags: fb series mine explosion-proof electric fan, China fb series mine explosion-proof electric fan manufacturers, suppliers, factory

Send Inquiry