Y10-21 Industrial Boiler Induced Draft Fan

Y10-21 Industrial Boiler Induced Draft Fan

Y10-21 Industrial Boiler Induced Draft Fan is designed for flue-gas extraction in industrial boiler systems.
The series covers No.8 and No.9 configurations with reference airflow of 4,215–16,252 m³/h, total pressure of 2,303–3,312 Pa and motor power of 7.5–22 kW.
C-type belt drive and D-type coupling drive arrangements are available. Final selection should consider airflow, pressure, flue-gas temperature, dust condition, outlet direction, voltage and frequency.
Send Inquiry
Description
Y10-21 SERIES · INDUSTRIAL BOILER INDUCED DRAFT

Y10-21 Industrial Boiler Induced Draft Fan

Y10-21 is a single-inlet centrifugal induced draft fan for industrial boiler flue-gas extraction. The product manual provides No.8 and No.9 reference configurations at 1450 rpm, with C-type belt drive and D-type coupling drive arrangements.

4,215–16,252 m³/h
2,303–3,312 Pa
7.5–22 kW
≤250°C
Y10-21 industrial boiler induced draft fan
AIRFLOW
4,215–16,252 m³/h
TOTAL PRESSURE
2,303–3,312 Pa
MOTOR POWER
7.5–22 kW
SPEED
1450 rpm
DRIVE
C / D
01 / Engineering Overview

Industrial Boiler Flue-Gas Extraction

Y10-21 is a single-inlet centrifugal induced draft fan used in industrial boiler flue-gas systems. It works on the exhaust side of the boiler system and is selected to overcome resistance from the furnace, heat-transfer surfaces, dust-removal equipment, flue duct and discharge route.

The product manual provides No.8 and No.9 reference configurations at 1450 rpm. Final fan selection must still be based on the actual operating airflow, pressure, temperature and system resistance.

Product Role
Y10-21 belongs to the boiler induced-draft route and should not be selected only from boiler tonnage or motor power.
02 / Boiler Reference Duty

No.8 and No.9 Reference Configurations

No.8
2 t/h Reference
4,215–11,115 m³/h
2,303–2,509 Pa
No.9
4 t/h Reference
6,000–16,252 m³/h
3,038–3,312 Pa
Manual reference only: 2 t/h and 4 t/h are reference boiler duties in the product manual. Final selection must use the real operating point.
03 / Drive Arrangement

C-Type Belt Drive and D-Type Coupling Drive

C TYPE
V-Belt Drive
Power is transmitted through V-belts and pulleys. The motor is separated from the fan shaft and the arrangement provides practical access for belt and motor maintenance.
D TYPE
Coupling Drive
The motor and fan shaft are connected through a coupling for direct mechanical transmission.
04 / Manual Structure

Main Structural Features from the Product Manual

Impeller Material
16Mn steel construction is specified in the product manual.
Impeller Blades
24 blades in total: 12 long blades and 12 short blades.
Blade Direction
Forward-curved blade arrangement according to the manual description.
Bearing Housing
Water-cooled bearing housing is used to reduce thermal load in hot flue-gas service.
05 / Product Manual Performance

Y10-21 No.8 Performance

Reference speed: 1450 rpm.

POINT
AIRFLOW
PRESSURE
SHAFT POWER
MOTOR
1
4,215
2,303
3.83 kW
7.5 kW
2
5,400
2,391
4.75 kW
7.5 kW
3
6,736
2,460
5.85 kW
7.5 kW
4
7,536
2,489
6.53 kW
7.5 kW
5
8,148
2,499
7.22 kW
7.5 kW
6
9,598
2,509
8.81 kW
11 kW
7
10,281
2,499
9.65 kW
11 kW
8
11,115
2,509
10.76 kW
11 kW

Y10-21 No.9 Performance

Reference speed: 1450 rpm.

POINT
AIRFLOW
PRESSURE
MOTOR
1
6,000
3,038
18.5 kW
2
7,775
3,165
18.5 kW
3
9,590
3,254
18.5 kW
4
10,730
3,283
18.5 kW
5
11,600
3,303
18.5 kW
6
13,665
3,312
18.5 kW
7
14,642
3,303
18.5 kW
8
16,252
3,224
22 kW
Performance data source: values above follow the supplied Y10-21 product manual. Final fan selection must be checked against the actual project duty.
06 / Flue-Gas Condition

Temperature and Dust Conditions

Maximum Medium Temperature
The product manual specifies that the conveyed medium temperature should not exceed 250°C.
Dust Removal Requirement
The manual requires upstream dust-removal equipment with efficiency not lower than 85%.
Actual flue-gas temperature must still be provided during selection because gas density changes with temperature and affects fan pressure and absorbed power.
07 / Engineering Drawing

Y10-21 No.9D Installation and Overall Dimensions

The drawing below is based on the supplied product manual and includes the No.9D installation interface, overall dimensions and outlet orientation references.

Y10-21 No.9D boiler centrifugal induced draft fan installation and overall dimensions
Engineering note: use the approved project GA drawing for final foundation construction, duct fabrication and installation. The drawing shown here is a manual reference drawing.
08 / Outlet Orientation

Available Discharge Directions

0°
45°
90°
135°
180°
225°

Confirm rotation and discharge angle before manufacturing because outlet direction affects the foundation, duct connection and maintenance space.

09 / Selection Information

What to Send for Y10-21 Selection

01 / Airflow
Required operating airflow in m³/h.
02 / Pressure
Required total or static pressure and measurement basis.
03 / Temperature
Normal and maximum flue-gas temperature.
04 / Dust Condition
Dust-removal equipment, efficiency and expected dust loading.
05 / Drive
C-type belt drive or D-type coupling drive.
06 / Outlet
Required rotation and discharge angle.
07 / Electrical
Voltage, frequency, phase and motor requirements.
11 / Technical FAQ

Y10-21 Boiler Induced Draft Fan Questions

What fan sizes are shown in the product manual?
The supplied Y10-21 manual provides No.8 and No.9 reference configurations.
What is the reference airflow range?
The manual performance data covers approximately 4,215 to 16,252 m³/h.
What pressure range is shown?
The supplied manual covers approximately 2,303 to 3,312 Pa total pressure.
What is the maximum medium temperature?
The product manual specifies that the conveyed medium temperature should not exceed 250°C.
Is upstream dust removal required?
Yes. The manual requires upstream dust-removal efficiency of at least 85%.
What is the difference between C and D drive?
C-type uses V-belt transmission, while D-type uses coupling transmission between the fan and motor shafts.
Can the outlet direction be specified?
Yes. The manual shows 0°, 45°, 90°, 135°, 180° and 225° discharge directions.
Related Boiler Fan Pages

Y10-21 in the Boiler Induced Draft Cluster

PRODUCT FAMILY
Boiler Induced Draft Fans
Compare Y4-68, Y6-30, Y5-47, Y5-48, Y10-21 and other boiler ID fan directions.
View Product Family →
APPLICATION
Boiler Induced Draft System
Review the boiler, dust collector, duct and chimney resistance as one complete flue-gas system.
View System Guide →
RELATED PRODUCT
Y6-30 Boiler ID Fan
Compact induced-draft direction for smaller industrial boiler systems.
View Y6-30 →
HIGHER RESISTANCE
Y8-39 / Y9-38
Review when the exhaust route requires a higher-resistance boiler induced-draft direction.
View Y8-39 / Y9-38 →
Y10-21 BOILER ID FAN SELECTION

Send the Actual Boiler and Flue-Gas Duty

Airflow · Pressure · Gas Temperature · Dust Condition · Drive Arrangement · Outlet Angle · Voltage · Frequency · Quantity
Manager Zhao
SHANDONG QIYUE FAN CO., LTD.
Industrial fan selection and export project support
Tel / WeChat / WhatsApp: +86 15653305981
Email: sales@qiyuefan.com
Factory: Dongchen Industrial Park, Zhoucun District, Zibo, Shandong, China

Hot Tags: y10-21 industrial boiler induced draft fan, China y10-21 industrial boiler induced draft fan manufacturers, suppliers, factory

Send Inquiry